5. Each Component Function
User’s Manual
69
Table 5.13. Baud Rate Settings
SERIAL1, 2
Clock input (1.8432MHz)
SERIAL3 - 6
Clock input (14.7456MHz)
Baud rate to be set
Value to be set
in the divisor register
(Decimal)
Setting error (%)
Value to be set
in the divisor register
(Decimal)
Setting error (%)
50 2304
---
18432
---
75 1536
---
12288
---
110 1047
0.026
8378
0.0022
134.5 857
0.058
6852
0.0006
150 768
---
6144
---
300 384
---
3072
---
600 192
---
1536
---
1200 96
---
768
---
1800 64
---
512
---
2000 58
0.69
461
0.04
2400 48
---
384
---
3600 32
---
256
---
4800 24
---
192
---
7200 16
---
128
---
9600 12
---
96
---
14400 8
---
64
---
19200 6
---
48
---
28800 4
---
32
---
38400 3
---
24
---
57600 2
---
16
---
76800 ---
--- 12
115200 1 --- 8 ---
153600 --- --- 6 ---
230400 --- --- 4 ---
Example : To set 9,600 bps, write "00" to the (MSB) divisor latch register and "12 (decimal)" to the (LSB) divisor latch