13. Appendix
Software Manual
63
Q. How can I adjust the brightness of the LCD.
A. On the panel computer in the SH4 CPU & .NET installed IPC series, you can adjust the LCD’s
brightness either by starting the “System Setting” applet from within the Control Panel, selecting the
“Backlight” tab, and clicking on the [Bright] button or by pressing the F1+F2 or F1+F3 function
keys simultaneously.
(On the IPC-PT/SV10DC1 and IPC-PT/SV15DC1 adjust using +
or +
.)
Q. I want to run applications automatically. Is this possible?
A. I recommend use of the schedule function of “CONTEC Manager”.
In addition, although it becomes possible by describing to the registry of following Windows
CE .NET 4.2, keep in mind that registry change may affect operation of OS.
You can edit the registry by running “RegEdit.exe” in the Windows directory.
\\HKEY_LOCAL_MACHINE\initKey
Item
Data type
Description
Launchxx
REG_SZ
The “String” type describes the application name (program name) to perform.
Enter the application name to run. “xx” is the ID number.
[Note] Full path name cannot be used for the application name.
Dependxx
REG_BINARY A dependency describes the dependency by the identification number (“Binary”
type ) in order of execution of the application specified by Launch ( in order to
start a program, when another program needs to start beforehand).
If the running order of applications has dependence relation, specify the
relation by ID numbers.
Example:
Launch90
: “shell.exe”
Launch95
: “myProg.exe”
Depend95
: 5A, 00
Note, however, that the program specified here to be started must be located in the Windows directory
since it cannot be defined by its full pathname.
Also, by making use of the schedule function in “CONTEC Manager”, program can be started in a more
complicated timing. Details please refer to the manual of “CONTEC Manager”.
The following is an example of a registry in an actual default (Mini shell).
Launch16 WceObjUp.exe
Launch20 device.exe
depend20 Hex 10, 00
Launch30 gwes.exe
depend30 Hex 14, 00
Launch50 taskman.exe
depend50 Hex 14, 00 / 1E, 00
Launch60 service.exe
depend60 Hex 14, 00
Launch80 wcemngr.exe
depend80 Hex 14, 00 / 1E, 00
(Notes)
Please do not perform the above rewritings of the registry indicated by the default, or deletion. It is new
and specification of a program to perform surely needs to perform a new addition for the existing registry
number.
Содержание IPC-BX/M10DC5
Страница 9: ...1 Features of the Windows CE NET 4 2 2 Software Manual...
Страница 25: ...6 System Setting 18 Software Manual...
Страница 43: ...9 Force Reset Functions 36 Software Manual...
Страница 45: ...10 BIOS Update Function 38 Software Manual...
Страница 47: ...11 Emergency Boot Function 40 Software Manual...