Model VC940: OPERATING MANUAL
9
Ω
, k
Ω
, M
Ω
Ω
:
Ohm. The unit of resistance.
k
Ω
:
Kilohm. 1×10
3
or 1000 ohms
M
Ω
:
Megaohm. 1×10
6
or 1,000,000 ohms
Hz, kHz,
MHz
Hz :
Hertz. The unit of frequency in cycles/second.
kHz:
Kilohertz. 1×10
3
or 1000 hertz
MHz:
Megahertz, 1×10
6
or 1,000,000 hertz.
mV, V
V:
Volts. The unit of voltage.
mV:
Millivolt. 1×10
-3
or 0.001 volts
µA, mA, A
A:
Amperes (amps). The unit of current.
mA:
Milliamp, 1×10
-3
or 0.001 amperes.
µA:
Microamp.1×10
-6
or 0.000001 amperes.
10
nF,µF,
mF
Farad. The unit of capacitance
nF:
Nanofarad. 1×10
-9
or 0.000000001 farads.
µF:
Microfarad.1×10
-6
or 0.000001 farads.
mF:
Millifarad. 1×10
-3
or 0.001 farads.
11
Automatic power off feature is on
12
Continuity test
STO
Data store is on
13
RCL
Data recall is on
14
The relative mode is on to display the present value minus the
stored value.
LOW
The indicator for the lowest setup limit.
15
HIGH
The indicator for the highest setup limit.
16
AUTO
The Meter is in the auto range mode in which the Meter
automatically selects the range with the best resolution.
17
SEND
Data output is in progress
18
Backlight feature is on
19
HOLD
Data hold mode is active
20
PEAK
HOLD
Peak hold mode is active
21
Diode test
22
%
z
Frequency signal duty cycle.
z
4~20mA loop current as % reading
22
The input value is too large for the selected range.
23
Analogue
Bar Graph
Provides an analog indication of the present input, quick response.
Analogue Bar Graph
The bar graph provides an analogue indication of the measured input. For most measurement functions, the bar graph updates 10 times per second.
Using MAX MIN
The MAX MIN mode stores minimum (MIN) and maximum (MAX) input values. When the input goes below the stored minimum value or above the stored maximum value, the
Meter beeps and stores the new value.
Press
MAX MIN
to enter MAX MIN mode. The sampling time is every 2 seconds. The maximum reading and MAX are shown on the left secondary display. The minimum
reading and MIN are shown on the right secondary display. The primary display shows the present measurement reading.
Press MAX MIN the second time, the present measurement reading is shown on the left secondary display. The minimum reading and MIN are shown on the right secondary
display. The primary display shows the maximum value.
Press MAX MIN the third time, the present measurement reading is shown on the left secondary display. The maximum reading and MAX are shown on the right secondary
display. The primary display shows the maximum value.
Each subsequent press of
MAX MIN
steps through the above three modes.
To exit MAX MIN mode, press
EXIT
. Also, press
HOLD
could stop the Meter updating reading.
MAX MIN mode can only be used under MANUAL ranging mode.