b) Assembly & Operation
• The product should only be used in closed, dry indoor areas, it must not
become damp or wet. There is the risk of a fatal electric shock!
• The product is constructed according to protection class II.
• The product must be operated stationarily installed.
• Only use two AA/mignon type batteries or rechargeable batteries for power
supply.
• The switching output on the rear is potential-free (NC and NO contact). It can
also be used to directly control power supply for a heating or cooling device.
If work is required on the mains voltage, it must only be performed by a trained
specialist (e.g. electrician). There is danger to life from electric shock!
Observe the information in Chapter 15 („Technical Data“) for maximum
contact load capacity.
• Do not use the product inside of rooms or in bad ambient conditions where
flammable gases, vapours or explosive dust may be or are present! There is
a danger of explosion!
• Do not expose the product to extreme temperatures, strong vibrations or
strong mechanical stress.
• If it can be assumed that safe operation is no longer possible, the device must
be turned off and precautions are to be taken to ensure that it is not used
unintentionally. Then have the product inspected by a specialist.
It must be assumed that safe operation is no longer possible if:
- the device shows visible signs of damage,
- the product does not work or not work properly (flickering light, smoke or
burnt smell, audible crackling, discolouration of the product or adjacent
surfaces)
- the device has been stored for a long time under unfavourable conditions
or
- after the device has been exposed to extraordinary stress caused by
transport
• Should questions arise that are not answered by this operating manual,
contact us (for contact information, see Chapter 1) or another expert.