3 0
In st ru c t io n m an u al
C o n e r g y IP G s t r in g in v e r t e r s e r ie s
5 T r a n s p o r t a n d in s t a lla t io n
E
N
G
L
IS
H
5.3.2
Wall mounting
Conergy IPG string inverter series inverters are intended to
be wall mounted. In order to facilitate installation they are
supplied with a wall bracket, a drilling template and a basic
installation equipment pack with wall plugs and screws.
For wall mounting you will need
| wall bracket,
| drill template,
| wall plugs and screws from the basic installation equipment
pack,
| drill bit (8 mm),
| appropriate open-ended spanner.
Fig. 5-3: Wall bracket installation
CAUTION!
Top- heaviness
| Take the considerable top-heaviness of the device into
consideration during installation.
Wall mounting
1. Drill the holes in accordance with the drilling template
supplied.
2. Screw the wall bracket firmly in place.