55
5
INSTALLATION
5.1
REQUIREMENTS FOR THE PLACE OF INSTALLATION
/
The ambient temperature must not exceed 30 °C (86 °F)!
/
In order to be able to safely discharge the wastewater (regeneration) in operation and in case of any
defects that occur in the system, precise compliance with the details given in the chapter 5 “INSTAL-
LATION” is necessary!
If the wastewater cannot be safely and completely discharged, the house and installations can be dam-
aged by water.
/
The room where the unit is installed must be dry and frost free. Unauthorised persons must not have
access to the water softener.
/
The water softener must not be exposed to strong shocks.
/
The unit can be installed in all standard drinking water pipes.
/
It is not permitted to install the water softener upstream of the water meter!
5.2
INSTALLATION POSITION
The unit may only be installed by skilled personnel.
The chapter 4.1 “INTENDED USE” must always be observed!
To ensure trouble-free operation, the requirements listed below must be adhered
to:
A power connection (230 V, 50 Hz), which is permanently live, must be available.
Always install the water softener in a vertical position (± 5°)! Failure to observe
this can impair its function.
Содержание CLEAR SOFT
Страница 39: ...39 10 6 2 ELEKTRONISCHE STEUERUNG Abb 17 Elektronische Steuerung mit St rmelderelais...
Страница 40: ...40 11 ERSATZTEILE Abb 18 Ersatzteile CLEAR SOFT A G D F B C E...
Страница 81: ...81 10 6 2 ELECTRONIC CONTROL Fig 17 Electronic control with fault indication relay...
Страница 82: ...82 11 SPARE PARTS Fig 18 Spare parts CLEAR SOFT A G D F B C E...
Страница 123: ...123 10 6 2 STEROWNIK ELEKTRONICZNY Rys 17 Sterownik elektroniczny z przeka nikiem do informacji o b dach...
Страница 124: ...124 11 CZ CI ZAMIENNE Rys 18 Cz ci zamienne CLEAR SOFT A G D F B C E...