66
10
DATA SHEET
10.1
TYPE
CLEAR DOS Dosing pump
10.2
TECHNICAL DATA
/
The water being dosed must comply with the European Drinking Water Directive.
/
The rated pressure indicates the pressure range that the dosing pump must comply with in accordance
with DIN EN 14812 and DIN 19635-100. The maximum operating pressure is lower to ensure the op-
timum function of the dosing pump.
Technical data
CLEAR DOS
Connection diameter nominal
DN 25 / 1"
Working range according to DIN EN 14812 and DIN 19635-100:
Lower/upper working limit
0.06 - 4 m³/h
Nominal pressure
PN 10
Operating pressure
max. 8 bar
Pressure loss at upper working limit
0.8 bar
Volume of the mineral solution container
6 litre
Treated water volume per mineral solution container
48 - 80 m³
Electrical connection
230 V / 50 Hz
Power consumption: Operation
Dosing
max. 2 W
max. 10 W
Threaded connection according to
DIN EN 10226-1
Water and ambient temperature
max. 30 °C
Operating weight
Approx. 9.8 kg
Shipping weight
Approx. 4.2 kg