39
6.2
MOUNTING THE BUILT-IN ROTARY FLANGE
Install using the supplied built-in rotary flange. The built-in rotary flange is used as a connecting element
between the pipe and the backwashing filter. It is suitable for both horizontal and vertical pipes.
The built-in rotary flange must be installed in the direction of flow. This is marked by a
cast in arrow (see fig. 5).
The flange surface of the built-in rotary flange must be in a vertical position! The built-in rotary flange must
be fitted so that mechanical stresses cannot occur!
Otherwise mechanical damage can result, the pipe may burst or the built-in rotary flange can break. This
can result in major water damage. In this case, persons close to the backwashing filter are exposed to a
health risk due to the large quantities of water.
Therefore, during installation, ensure that no large forces act on the pipe, built-in rotary flange and back-
washing filter.
The section of the profiled flange gasket must point towards the built-in rotary flange (see fig. 5). Failure
to observe this can lead to leaks and water escaping. This can in turn cause water damage to the house and
its installations.
Fig. 5: Built-in rotary flange
Failure to comply with this means that backwashing is impossible. By and by this
leads to an increasing pressure loss.
Profiled flange gasket
Flow direction arrow