3.3                                                                                                                                                     

ZNAK KONTROLNY

Urz

ą

dzenia s

ą

 zgodne z zasadami technicznymi dotycz

ą

cymi instalacji wody pitnej zgodnie z DIN EN 806 

nn. oraz krajowym uzupe

ł

nieniem DIN 1988 nn. i DIN EN 1717. Zosta

ł

y skontrolowane przez DVGW 

(Deutsche Vereinigung des Gas- und Wasserfaches e. V. — Technisch-wissenschaftlicher Verein = Nie-

miecki Zwi

ą

zek Bran

ż

y Gazowniczej i Wodnej, zarejestrowane stowarzyszenie techniczno-naukowe), w 

oparciu o wymogi norm DIN EN 13443-1 i DIN 19628 dla filtrów mechanicznych w obszarze wody pitnej 

i otrzyma

ł

y znak DIN-DVGW.

NW-9301CN0106

Rys. 2:  Znak DIN-DVGW

Содержание CLEAR 2.0 R 1 1/4"

Страница 1: ...CLEAR 2 0 R 1 R CKSP LFILTER MONTAGE UND BETRIEBSANLEITUNG BACKWASHING FILTER OPERATING INSTRUCTIONS FILTR Z P UKANIEM WSTECZNYM INSTRUKCJA MONTA U I EKSPLOATACJI conel de CLEAR WASSER AUFBEREITUNG...

Страница 2: ...CHTUNGEN 10 5 ANFORDERUNGEN AN DEN EINBAUORT 11 6 EINBAU 12 6 1 EINBAUMASSE 12 6 2 MONTAGE DES EINBAUDREHFLANSCHS 13 6 3 MONTAGE DES R CKSP LFILTERS 14 6 4 ABLEITEN DES R CKSP LWASSERS 15 7 BETRIEB 17...

Страница 3: ...neSiebfiltrationgrob undfeink rnigePartikel diegr erodergleichder MaschenweitedesFiltersiebessind Partikel diekleineralsdie verwendeteSiebmaschenweite sind sowie Tr bstoffe und im Wasser gel ste Stoff...

Страница 4: ...ion Instandsetzung Installation und Instandhaltung darf nur durch vom Hersteller autorisiertes Personal erfolgen das in der Lage ist die in der Einbau und Betriebsanleitung genannten Anweisungen und d...

Страница 5: ...nationalen Einheitensystem SI Syst me International d Unit s werden folgende Einheiten und Begriffe verwendet Achtung Dieses Zeichen weist auf einen Punkt hin der f r einen zuverl ssigen Betrieb oder...

Страница 6: ...d Transportsch den da sp tere Reklamationen nicht mehr anerkannt werden k nnen Dieser R cksp lfilter ist f r den Einsatz in kaltem bis max 30 C Trinkwasser Wasser der kommunalen Wasserversorgung entwi...

Страница 7: ...DIN 1988 ff sowie der DIN EN 1717 Sie sind vom DVGW Deutsche Vereinigung des Gas und Wasserfaches e V Technisch wissenschaftlicher Verein gem den Anforderungen derDIN EN 13443 1 und DIN 19628 f r mech...

Страница 8: ...chtbestimmungsgem er Verwendung und bei Nichtbeachtung der Gefahrensymbole und Sicherheitshinweise F r hieraus resultierende Sch den haftet der Hersteller Lieferer nicht Das Risiko tr gt allein der An...

Страница 9: ...uch f r die Umwelt und den R cksp lfilter zur Folge haben 4 4 WASSERDRUCK Der Wasserdruck muss zwischen 1 5 bar und 10 bar liegen Der Wasserdruck darf 1 5 bar nicht unter schreiten da sonst das R cksp...

Страница 10: ...n Sind die elektrischen Ger te Einrichtungen an die Stromversorgung angeschlossen kann es au erdem zu einem Kurzschluss kommen F r Personen besteht in diesem Fall die Gefahr eines Stromschlags In der...

Страница 11: ...rsonen d rfen zu dem Raum keinen Zutritt haben Der R cksp lfilter darf keinen starken St en ausgesetzt sein Vor dem R cksp lfilter muss ein Absperrventil installiert sein Damit kann die Wasserzufuhr b...

Страница 12: ...R 1 A Einbaul nge mit Verschraubungen 180 195 230 A Einbaul nge ohne Verschraubungen 100 100 110 B Ger tebreite 124 124 124 C H he oberhalb Rohrmitte 155 155 155 D H he unterhalb Rohrmitte 246 246 24...

Страница 13: ...gung bis hin zum Bruch der Rohrleitung oder des Ein baudrehflanschs kommen Daraus k nnen gr ere Wassersch den resultieren Personen die sich in der N he des R cksp lfilters aufhalten sind in diesem Fal...

Страница 14: ...en gr ere Wassersch den resultieren Personen die sich in der N he des R cksp lfilters aufhalten sind in diesem Falle durch die gr eren Was sermengen einem gesundheitlichen Risiko ausgesetzt Deshalb m...

Страница 15: ...Meter bis zum n chsten Abwasseranschluss gef hrt werden Dabei ist auf knickfreien Verlauf mit stetigem Gef lle zu achten Der Anschluss eines Schlauchs wird folgenderma en durchgef hrt Das R cksp l Han...

Страница 16: ...16 Abb 7 Ableitungsm glichkeiten f r das R cksp lwasser I min 10 l II min 20 mm III IV V min 250 mm min 250 mm...

Страница 17: ...er ber den Einbaudrehflansch Der Filter enth lt eine versilberte Saugrohreinheit am Siebeinsatz des Schutzfilters f r eine optimale Keimschutzprophylaxe Soll die Keimschutzprophylaxe dauerhaft erhalte...

Страница 18: ...n patentiertes Kera mik Sp lventil an der Unterseite des R cksp lfilters sodass das R cksp lwasser austreten kann Das gefilterte Wasser str mt von innen nach au en durch die Siebfl che in die Saugrinn...

Страница 19: ...ntlang einer Monatsskala verschieben Dadurch kann die n chste f llige R cksp lung ange zeigt werden Ist das Intervall bis zur n chsten R cksp lung gr er als zwei Monate kann es zu einem Festsetzen der...

Страница 20: ...beiten am R cksp lfilter die ber die reine betriebsbedingte Bedienung hi nausgehen muss der R cksp lfilter drucklos gemacht werden Es d rfen nur Original Ersatzteile verwendet werden Eigenm chtige Umb...

Страница 21: ...filters mit Trinkwasser in Kontakt kommen und an dieses ab gegeben werden Personen die verschmutztes Wasser aufnehmen sind gesundheitlich gef hrdet Den R cksp lfilter frostfrei lagern Durch Frost kann...

Страница 22: ...chert am besten eine gute Betriebsfunktion auch ber die Gew hrleistungszeit hi naus Es ist anzustreben dass die regelm igen Wartungsarbeiten und die Versorgung mit Verbrauchsmaterial bzw Verschlei mat...

Страница 23: ...l uft nach Schmutz im Keramik Sp lventil R cksp lung wiederholen und an schlie end das Handrad bis zum Einrasten drehen Wasserdurchfluss l sst nach Sieb ist verstopft R cksp lung durchf hren Undichthe...

Страница 24: ...24 10 ERSATZTEILE Abb 9 Ersatzteile CLEAR 2 0 R 1 9 12 13 14 15 17 18 19 20 23 24 26 25 E B 22 21 1 3 11 8 9 2 10 6 16 7...

Страница 25: ...ing 52 3 5 1 6 Abdeckhaube vorne komplett 1 7 Stopfen Manometer komplett 1 8 Grundgeh use 1 9 Profilflanschdichtung 2 10 Abdeckhaube hinten 1 11 Linsenflanschschraube 4 10 1 12 Sieb 1 13 Saugrohr vers...

Страница 26: ...bei Wasserrohr br chen Leckagen Defekten an der Hauswasserinstallation sowie vor au ergew hnlich hohem Was serverbrauch Erkennt rinnende Wasserh hne und Armaturen Technische Daten CLEAR 2 0 R CLEAR 2...

Страница 27: ...CLEAR von CONEL f r Ausk nfte gerne zur Verf gung Deutschland T 49 0 7195 692 0 Frankreich T 33 0 3 88 65 93 94 Wir empfehlen Ihnen dringend einen Wartungsvertrag abzuschlie en damit alle Wasseraufbe...

Страница 28: ...NTS FOR THE PLACE OF INSTALLATION 37 6 INSTALLATION 38 6 1 INSTALLATION DIMENSIONS 38 6 2 MOUNTING THE BUILT IN ROTARY FLANGE 39 6 3 MOUNTING THE BACKWASHING FILTER 40 6 4 BACKWASH WATER DISCHARGE OPT...

Страница 29: ...en filtration coarse and fine grained particles larger or equal to the mesh size of the filter screen Particles smaller than the supplied mesh size impurities causing tur bidity and substances dissolv...

Страница 30: ...nce servicing inspection repair Installation and maintenance may only be carried out by personnel authorized by the manufacturer who are capable of fulfilling the instructions given in the operating i...

Страница 31: ...ndition In derogation of the International System of Units SI Syst me International d Unit s the following units are used Attention This symbol refers to a point which must be observed for reliable op...

Страница 32: ...lter is suitable for use in cold drinking water water of the mu nicipal water supply up to a maximum water temperature of 30 C 86 F It is ab solutely essential that the manufacturer supplier will be c...

Страница 33: ...1988 ff and DIN EN 1717 They are tested by the DVGW Deutsche Vereinigung des Gas und Wasserfaches e V technical scientific association for the gas and waterindustries inaccordancewiththerequirementso...

Страница 34: ...to be intended use Additional dangers exist in case of non intended use and failure to observe the danger symbols and safety information Themanufacturer supplierarenotliableforanylossesordamageresulti...

Страница 35: ...onment and the unit 4 4 WATER PRESSURE The water pressure should be between 1 5 bar and 10 bar The water pressure must not drop below 1 5 bar as otherwise the backwashing can be impaired If the filter...

Страница 36: ...er s specifications In addition this may also result in short circuits if these electrical devices equipment being connected to the electrical power supply In the event of such cases persons are at ri...

Страница 37: ...nd frost free Unauthorised persons must not have access to the backwashing filter The backwashing filter must not be exposed to strong shocks A shutoff valve must be installed upstream of the backwash...

Страница 38: ...g length with screw connection 180 195 230 A Fitting length without screw connection 100 100 110 B Unit width 124 124 124 C Height above pipe centre 155 155 155 D Height below pipe centre 246 246 246...

Страница 39: ...the pipe may burst or the built in rotary flange can break This can result in major water damage In this case persons close to the backwashing filter are exposed to a health risk due to the large quan...

Страница 40: ...n result in major water damage Persons close to the backwashing filter are exposed to a health risk due to the large quantities of water re leased Therefore if necessary the pipes must be additionally...

Страница 41: ...hose several metres to the next wastewater connection A kink free course at a steady incline is important The connection of a hose is carried out as follows Remove the handwheel for backwashing by pu...

Страница 42: ...42 Fig 7 Backwash water discharge options I min 10 l II min 20 mm III IV V min 250 mm min 250 mm...

Страница 43: ...ackwashing filter through the built in rotary flange The filter contains a silver plated suction pipe unit located at the sieve insert of the protective filter for an optimum prophylactic germ protect...

Страница 44: ...same time a patented ceramic flushing valve on the underside of the backwashing filter opens so that the backwash water can flow out The filtered water flows from the inside outwards through the scree...

Страница 45: ...isplay slider attached to the backwashing filter It can be slid along the months scale This enables the backwashing interval to be monitored If the interval until the next backwashing is longer than t...

Страница 46: ...efore carrying out any work on the backwashing filter which extends beyond pure operational control the backwashing filter must be depressurised Only original spare parts are to be used Arbitrary modi...

Страница 47: ...hargedintothedrinkingwaterwhenthebackwashingfilterisswitchedbackon Thehealthofpersons who drink dirty water is at risk Store the backwashing filter in frost free conditions Frost can cause any water c...

Страница 48: ...the best way to ensure a good operating function beyond the warranty period Wherever possible the regular servicing work and supply with consumables and wearing materials etc should be carried out by...

Страница 49: ...water continues running Dirt in the ceramic flushing valve Repeatbackwashingandcontinue turning the handwheel until it au dibly locks into place Water flow rate falls Screen is blocked Carry out backw...

Страница 50: ...50 10 SPARE PARTS Fig 9 Spare parts CLEAR 2 0 R 1 9 12 13 14 15 17 18 19 20 23 24 26 25 E B 22 21 1 3 11 8 9 2 10 6 16 7...

Страница 51: ...r 1 3 O ring 52 3 5 1 6 Front cover complete 1 7 Plug for manometer complete 1 8 Basic housing 1 9 Profiled flange gasket 2 10 Rear cover 1 11 Pan washer head screw 4 10 1 12 Screen 1 13 Suction pipe...

Страница 52: ...he effects of water pipe bursts leakages defects on the domestic water installation and unusually high water consumption Detects leaking taps and valves Technical data CLEAR 2 0 R CLEAR 2 0 R 1 CLEAR...

Страница 53: ...u with information Germany T 49 0 7195 692 0 France T 33 0 3 88 65 93 94 A servicing agreement is the best way to ensure a good operating function beyond the warranty period We strongly recommend you...

Страница 54: ...RZYRZ DY URZ DZENIA ELEKTRYCZNE 62 5 WYMAGANIA W STOSUNKU DO MIEJSCA MONTA U 63 6 INSTALACJA 64 6 1 WYMIARY MONTA OWE 64 6 2 MONTA FLANSZY MONTA OWEJ 65 6 3 MONTA FILTRA 66 6 4 ODPROWADZANIE POP UCZYN...

Страница 55: ...Oddziela on od wody poprzez filtracj na sicie grubo i drobnoziarniste cz stki wi ksze lub r wne red nicy oczek sita filtra Z wody nie zostaj odfiltrowane drobinki mniejsze od stosowanej rednicy oczek...

Страница 56: ...wa Prace w ramach instalacji i utrzymania ruchu mog przeprowadza wy cznie pracownicy upowa nieni przez producenta kt rzy s w stanie wype ni zalecenia wskazane w instrukcji monta u i eksploatacji oraz...

Страница 57: ...ze w pe ni czytelne Odmiennie od mi dzynarodowego uk adu jednostek miar SI Syst me International d Unit s stosowane s nast puj ce jednostki Uwaga Ten znak oznacza punkt kt ry musi koniecznie by przest...

Страница 58: ...wa p ne rekla macje nie b d uwzgl dniane Filtr jest przystosowany do u ytku z zimn wod pitn woda wodoci gowa do temperatury wody i otoczenia na poziomie maks 30 C 86 F Przed monta em do innych medi w...

Страница 59: ...7 Zosta y skontrolowane przez DVGW Deutsche Vereinigung des Gas und Wasserfaches e V Technisch wissenschaftlicher Verein Nie miecki Zwi zek Bran y Gazowniczej i Wodnej zarejestrowane stowarzyszenie te...

Страница 60: ...boli bezpiecze stwa lub nie przestrzegania przepis w bezpiecze stwa wyst puj dodatkowe zagro enia Za szkody wynikaj ce z tego tytu u producent dostawca nie odpowiada Ryzyko ponosi wy cznie u ytkownik...

Страница 61: ...iska naturalnego oraz filtra 4 4 CI NIENIE WODY Ci nienie wody musi waha si w przedziale od 1 5 bara do 10 bar w Ci nienie wody nie mo e by ni sze ni 1 5 bara poniewa mog oby to wp yn negatywnie na p...

Страница 62: ...przyrz dy urz dzeniaelektrycznes pod czonedozasilaniaelektrycznego mo eponadtodoj do zwarcia W takim przypadku istnieje niebezpiecze stwo pora enia u ytkownik w pr dem elektrycznym Przyrz dy urz dzeni...

Страница 63: ...od w budynku i urz dzeniu Przestrze pod instalacji musi by sucha i zabezpieczona przed przemarzaniem Osoby nieupowa nio ne nie mog mie dost pu do przestrzeni Filtr nie mo e by poddany mocnym uderzenio...

Страница 64: ...ugo monta owa ze rubunkami 180 195 230 A D ugo monta owa bez rubunk w 100 100 110 B Szeroko urz dzenia 124 124 124 C Wysoko powy ej rodka rury 155 155 155 D Wysoko poni ej rodka rury 246 246 246 E G b...

Страница 65: ...dzenia mechanicznego a nawet do p kni cia ruroci gu lub flan szy Skutkiem tego mog by du e szkody spowodowane przez wod Zdrowie os b przebywaj cych w po bli u filtra jest w takiej sytuacji zagro one w...

Страница 66: ...dowane przez wod Zdrowie os b przebywaj cych w pobli u filtra jest w takiej sytuacji zagro one w zwi zku z kontaktem z du ymi ilo ciami wody W razie potrzeby ruroci gi nale y zatem dodatkowo zamocowa...

Страница 67: ...zyny mog by odprowa dzone za pomoc w a do nast pnego przy cza Przy czym wa ne jest aby w nie by zgi ty i spadek by rosn cy Przy czenie w a nale y przeprowadzi nast puj co Pokr t o usun poprzez mocnepo...

Страница 68: ...68 Rys 7 Mo liwo ci odprowadzenia pop uczyn I min 10 l II min 20 mm III IV V min 250 mm min 250 mm...

Страница 69: ...posrebrzany uk ad odsysaj cy zanieczyszczenia z powierzchni wk adu filtracyjnego dla opty malnej ochrony przed bakteriami W przypadku gdy ochrona przed bakteriami ma by sta a uk ad odsysa j cy musi zo...

Страница 70: ...towanyceramicznyzaw rzrzutupop uczynotwierasi pospodniejstroniefiltra dzi kiczemupop uczyny mog swobodnie wyp ywa Oczyszczona woda wyp ywa ze rodka na zewn trz przez powierzchni wk a du filtra do uk...

Страница 71: ...ymocowany suwak przypominacza Mo e on by przesuwany wzd u skali miesi ca Dzi ki temu mo e by zaznaczone nast pne p ukanie wsteczne Je li interwa do nast pnego p ukania jest wi kszy ni dwa miesi ce w w...

Страница 72: ...MIENNE Przed rozpocz ciem prac przy filtrze wykraczaj cych poza zwyk obs ug eks ploatacyjn filtr nie mo e znajdowa si pod ci nieniem Wolno stosowa wy cznie oryginalne cz ci zamienne Samodzielna przebu...

Страница 73: ...brudzenia Zabrudzenia te mog przy ponownym uruchomieniu filtra zetkn si z wod pitn i przenikn do niej Zdrowie os b kt re spo yj zanie czyszczon wod mo e by zagro one Filtr przechowywa w miejscu bezpie...

Страница 74: ...N 806 5 Umowa o konserwacj zapewnia sprawno eksploatacyjn r wnie poza okresem gwarancyjnym Nale y d y do tego aby za regularne prace konserwacyjne i uzupe nianie materia w eksploatacyjnych b d zu ywaj...

Страница 75: ...okr t o do zaskoku Pop uczyny nadal p yn Zabrudzenia w ceramicznym za worze zrzutu pop uczyn P ukanie wsteczne powtarza a nast pnie przekr ci pokr t o do zaskoku Przep yw wody jest coraz mniej szy Zat...

Страница 76: ...76 10 CZ CI ZAMIENNE Rys 9 Cz ci zamienne CLEAR 2 0 R 1 9 12 13 14 15 17 18 19 20 23 24 26 25 E B 22 21 1 3 11 8 9 2 10 6 16 7...

Страница 77: ...komplet 1 7 Zatyczka do manometru komplet 1 8 Podstawowa obudowa 1 9 Profilowana uszczelka ko nierzowa 2 10 Pokrywa tylnia 1 11 ruba soczewkowa 4x10 1 12 Wk ad filtra 1 13 Posrebrzany uk ad odsysania...

Страница 78: ...iu wo dy Wykrywa ciekn ce krany i armatury Dane techniczne CLEAR 2 0 R CLEAR 2 0 R 1 CLEAR 2 0 R 1 rednica przy cza nominalna DN 20 DN 25 DN 32 Przep yw nominalny przy utracie ci nienia na poziomie 0...

Страница 79: ...ji Niemcy T 49 0 7195 692 0 Francja T 33 0 3 88 65 93 94 Pilnie zaleca si zawarcie umowy serwisowej na wykonywanie regularnych fachowych przegl d w aby urz dzenia uzdatniaj ce wod mog y by regularnie...

Страница 80: ...CONEL GmbH Margot Kalinke Str 9 80939 M nchen S mtliche Bild Ma und Ausf hrungsangaben entsprechen dem Tag der Drucklegung nderungen die dem technischen Fortschritt und der Weiter entwicklung dienen b...

Отзывы: