48
11
TECHNICAL DATA
The following applies for all the models of the device:
/
The water to be filtered must conform to the European Drinking Water Regulations!
/
The nominal flow rates given in the table are valid for a clean filter.
11.1
ACCESSORIES
/
Clear 2.0 SAFE
. Central water monitoring system for installation between built-in rotary flange and
cartridge filter with pressure reducer. For monitoring the water consumption and shutting off the wa-
ter pipe when adjustable limits are exceeded. Protects against the effects of water pipe bursts, leakag-
es, defects on the domestic water installation and unusually high water consumption. Detects leaking
taps and valves.
Technical data
CLEAR 2.0 KD ¾"
CLEAR 2.0 KD 1"
CLEAR 2.0 KD 1¼"
Connection diameter nominal
DN 20
DN 25
DN 32
Nominal flow rate to DIN EN 1567
2.3 m³/h
3.6 m³/h
5.8 m³/h
Nominal pressure
PN 16
PN 16
PN 16
Operating pressure
1.5 - 16 bar
(150 - 1600 kPa)
1.5 - 16 bar
(150 - 1600 kPa)
1.5 - 16 bar
(150 - 1600 kPa)
Adjustable discharge pressure
Factory setting
1.5 - 6 bar
(150 - 600 kPa)
4 bar
(400 kPa)
1.5 - 6 bar
(150 - 600 kPa)
4 bar
(400 kPa)
1.5 - 6 bar
(150 - 600 kPa)
4 bar
(400 kPa)
Mesh size
lower mesh width
upper mesh width
0.1 mm (100
μ
m)
0.095 mm (95
μ
m)
0.125 mm (125
μ
m)
0.1 mm (100
μ
m)
0.095 mm (95
μ
m)
0.125 mm (125
μ
m)
0.1 mm (100
μ
m)
0.095 mm (95
μ
m)
0.125 mm (125
μ
m)
Water and ambient temperature
max. 30 °C (86 °F)
max. 30 °C (86 °F)
max. 30 °C (86 °F)
Fitting length with screw connection 180 mm
195 mm
230 mm
Fitting length w/o screw connection
100 mm
100 mm
110 mm
Threaded connection according to
DIN EN 10226-1
DIN EN 10226-1
DIN EN 10226-1
Weight
3.4 kg
3.6 kg
4.1 kg
Содержание CLEAR 2.0 KD Series
Страница 16: ...16 Abb 7 Wechsel des Siebeinsatzes I 1 2 3 II 4 III 5 6 IV 7 8 9 10...
Страница 22: ...22 10 ERSATZTEILE Abb 8 Ersatzteile CLEAR 2 0 KD 1 9 12 13 14 15 1 A 3 D 11 8 9 4 2 5 10 6 7 B C...
Страница 40: ...40 Fig 7 Screen replacement I 1 2 3 II 4 III 5 6 IV 7 8 9 10...
Страница 46: ...46 10 SPARE PARTS Fig 8 Spare parts CLEAR 2 0 KD 1 9 12 13 14 15 1 A 3 D 11 8 9 4 2 5 10 6 7 B C...
Страница 64: ...64 Rys 7 Wymiana wk adu filtracyjnego I 1 2 3 II 4 III 5 6 IV 7 8 9 10...
Страница 70: ...70 10 CZ CI ZAMIENNE Rys 8 Cz ci zamienne CLEAR 2 0 KD 1 9 12 13 14 15 1 A 3 D 11 8 9 4 2 5 10 6 7 B C...
Страница 74: ...74 Notizen Notes Notatki...
Страница 75: ...75 Notizen Notes Notatki...