DESCRIPTION OF PRODUCT

..

   

The  536/537  Series  AutoSwitches  are  automatic  switchover  systems  designed  to  provide  a 
continuous supply of high purity gas. These units may be configured with or without the connections 
to connect to both high pressure and liquid cylinders. The primary bank (left side) of the AutoSwitch 
system is configured for use with liquid cylinders, pressure up to 600 PSI(41 bar). The reserve bank 
(right  side)  is  configured for  high  pressure  cylinders filled  up  to  3500  PSI  (241  bar). The  standard 
AutoSwitch  system  will  maintain  a  regulated  line  pressure  within  the  values  shown  in  the  table 
below:

 

 

MODEL

 

RANGE

 

536 2XXX

 

0-50 PSI  (0-3.5 BAR)

 

537 2XXX

 

0-50 PSI  (0-3.5 BAR)

 

536 3XXX

 

0-100 PSI  (0-7 BAR)

 

537 3XXX

 

0-100 PSI  (0-7 BAR)

 

 

The continuous working inlet pressure on the primary bank (liquid cylinder) must be above 140 PSI 
for the system to operate properly. When the primary bank falls below this value, gas will be pulled 
from the reserve side.

 

 

Models  of  these  AutoSwitches  are  available  with  or  without  pressure  switch  gauges.  Models  with 
pressure  switch  gauges  can  be  configured  for  use  in  conjunction  with  an  optional  remote  alarm. 
They cannot be connected directly to AC line voltage. Models with pressure switch gauges include 
a power indicator light and LED status lights to indicate the condition of the gas cylinders. A green 
indicator  light  signifies  a 

“Normal”  condition,  while  a  red  light  indicates  an  “Alarm”  (gas  cylinder 

empty) condition. The pressure switch AutoSwitch systems also include a strain relief on the bottom 
through which wiring can be connected to an internal circuit board and to a remote alarm such as 
CONCOA’s Altos 2 *.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 1

 

  

INTENDED USE OF PRODUCT

   

The brass 536 Series AutoSwitch systems are intended for use in high purity, non-corrosive gas 
applications. The stainless steel 537 Series AutoSwitch systems are for use in ultra-high purity 
applications. Please note the safety information shown in the later sections.

 

-3-

 

Содержание 536 Series

Страница 1: ...s AutoSwitch Systems For Use with Liquid Cylinders and High Pressure Gases in High Purity Applications INSTALLATION AND OPERATION INSTRUCTIONS Controls Corporation of America 1501 Harpers Road Virgini...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK 2...

Страница 3: ...imary bank falls below this value gas will be pulled from the reserve side Models of these AutoSwitches are available with or without pressure switch gauges Models with pressure switch gauges can be c...

Страница 4: ...ifold Always leak test any manifold or distribution pipeline before using Always be sure that the gas in a pipeline is the correct gas for the intended use Always install a blind gland and nut or pipi...

Страница 5: ...use of carbon dioxide 13 C G A Pamphlet G 6 1 Standard for Low Pressure Carbon Dioxide Systems at Consumer Sites INSTALLATION The site chosen for the installation of the system shall be level well ve...

Страница 6: ...oint extending approximately 10 inches to the left and right of center 3 Remove the mounting bracket from the rear of the AutoSwitch console by removing the retaining nuts at the bottom of the mountin...

Страница 7: ...ad sealant that remains on the threads d Start the PTFE tape on the first thread leaving a slight section of the chamfer exposed as shown in Fig 6 Make sure the tape does not overlap the end of the fi...

Страница 8: ...the cylinder of gas to the work site a Secure cylinder to the floor wall or bench with appropriate chain strap or stand to prevent toppling b Remove the cylinder cap c Be sure the cylinder valve is ti...

Страница 9: ...ns if compatible with the application which indicates leaks by bubbling To further check for leaks or if the leak detection solution cannot be used close the cylinder valve for a period of time recomm...

Страница 10: ...e switchover point of the AutoSwitch The alarm is used to provide an audible and visual warning that a changeover is about to occur If the nearly depleted cylinders are changed when the alarm LEDs ill...

Страница 11: ...cylinders simultaneously pressure is decreasingonboth inletgaugesatthesametime 1 Observe the inlet pressure It may be necessary to do this during times of the heaviest use If the inlet pressure is le...

Страница 12: ...rvice Please contact a Customer Service Representative at 1 800 225 0473 to receive this number You will be asked to provide 1 Model Number 2 Gas Service 3 Inlet pressure and type of gas supply 4 Outl...

Страница 13: ...THIS PAGE INTENTIONALLY LEFT BLANK 13...

Страница 14: ...THIS PAGE INTENTIONALLY LEFT BLANK 14...

Страница 15: ...ther than CONTROLS CORPORATION OF AMERICA or if the equipment has been subject to abuse misuse negligence or accident CONTROLS CORPORATION OF AMERICA s sole and exclusive obligation and Buyer s sole a...

Страница 16: ...ADI 3198 D Certified ISO 9001 Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 Telephone 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com...

Отзывы: