TROUBLESHOOTING (Continued)

   

 

Symptom

 

Cause

 

1.  Green status light(s) is lit when the pressure is 

below the set point on the gauges.

 

2.  Red status light(s) is lit when the pressure is above

 

the set point on the gauges.

 

1.  Cable to remote alarm wired incorrectly. Follow 

instructions in remote alarm instruction manual 
to correct problem.

 

1.  With full tank pressure, red alarm light(s) is on.

 

1.  Check that the set points on the gauges are 

set properly.

 

 

 

  

SERVICE

   

A Unit that is not functioning properly should not be used and should be returned to CONCOA for 
service. A Return Material Authorization (RMA) number must be issued for any product returned to 
CONCOA  for  service.  Please  contact  a  Customer  Service  Representative  at  1-800-225-0473  to 
receive this number. You will be asked to provide:

 

 

1.  Model Number

 

2.  Gas Service

 

3.  Inlet pressure and type of gas supply

 

4.  Outlet pressure

 

5.  Approximate gas usage

 

 

When shipping product back to CONCOA for repair the, following steps should be followed:

 

 

1.  Package the product sufficiently to prevent damage. If possible return product in its original 

packing.

 

2.  Include RMA number on the outside of the carton.

 

3.  Ship prepaid.

 

4.  Include a written decription of the problem you encountered with the product inside the package.

 

5.  Include a statement of the gas service the product was used in.

 

6.  Purge all equipment before shipping to protect the transporter and service personnel. 

Purging is especially important if the equipment has been in hazardous or corrosive gas 
service.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

-12-

 

Содержание 536 Series

Страница 1: ...s AutoSwitch Systems For Use with Liquid Cylinders and High Pressure Gases in High Purity Applications INSTALLATION AND OPERATION INSTRUCTIONS Controls Corporation of America 1501 Harpers Road Virgini...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK 2...

Страница 3: ...imary bank falls below this value gas will be pulled from the reserve side Models of these AutoSwitches are available with or without pressure switch gauges Models with pressure switch gauges can be c...

Страница 4: ...ifold Always leak test any manifold or distribution pipeline before using Always be sure that the gas in a pipeline is the correct gas for the intended use Always install a blind gland and nut or pipi...

Страница 5: ...use of carbon dioxide 13 C G A Pamphlet G 6 1 Standard for Low Pressure Carbon Dioxide Systems at Consumer Sites INSTALLATION The site chosen for the installation of the system shall be level well ve...

Страница 6: ...oint extending approximately 10 inches to the left and right of center 3 Remove the mounting bracket from the rear of the AutoSwitch console by removing the retaining nuts at the bottom of the mountin...

Страница 7: ...ad sealant that remains on the threads d Start the PTFE tape on the first thread leaving a slight section of the chamfer exposed as shown in Fig 6 Make sure the tape does not overlap the end of the fi...

Страница 8: ...the cylinder of gas to the work site a Secure cylinder to the floor wall or bench with appropriate chain strap or stand to prevent toppling b Remove the cylinder cap c Be sure the cylinder valve is ti...

Страница 9: ...ns if compatible with the application which indicates leaks by bubbling To further check for leaks or if the leak detection solution cannot be used close the cylinder valve for a period of time recomm...

Страница 10: ...e switchover point of the AutoSwitch The alarm is used to provide an audible and visual warning that a changeover is about to occur If the nearly depleted cylinders are changed when the alarm LEDs ill...

Страница 11: ...cylinders simultaneously pressure is decreasingonboth inletgaugesatthesametime 1 Observe the inlet pressure It may be necessary to do this during times of the heaviest use If the inlet pressure is le...

Страница 12: ...rvice Please contact a Customer Service Representative at 1 800 225 0473 to receive this number You will be asked to provide 1 Model Number 2 Gas Service 3 Inlet pressure and type of gas supply 4 Outl...

Страница 13: ...THIS PAGE INTENTIONALLY LEFT BLANK 13...

Страница 14: ...THIS PAGE INTENTIONALLY LEFT BLANK 14...

Страница 15: ...ther than CONTROLS CORPORATION OF AMERICA or if the equipment has been subject to abuse misuse negligence or accident CONTROLS CORPORATION OF AMERICA s sole and exclusive obligation and Buyer s sole a...

Страница 16: ...ADI 3198 D Certified ISO 9001 Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 Telephone 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com...

Отзывы: