7.4 Configuration
For initial setup,
the Dual TrueFeed controller needs to be setup in the CONFIGURATION menu once.
Depending on the configuration, some settings will be invisible if they are not relevant.
L
Highlighted Parameters are factory settings.
Motor type
: LT / HT
Cylinder type
: G / GL / H / A20 / A30 / GL / GLX
Material type
: NG / MG
Cal dev.
: 5.0 %
Control mode
:
GRAVI
/
RPM
Input mode
: Timer / Relay (Injection)
(not visible in Color mode)
Input filter
:
(3-32)
(not visible in Color mode,
only with relay selection)
Fill. System
: NO / ME / MV/ GR
(GR only in Regrind mode)
(MV
only
in
Color
mode)
Filling start
: 800 gr.
(only with ME or MV)
Hopper empty
: 700 gr.
(only with ME / MV / NO)
Regrind HL
: 2000 gr.
(only when GR selected)
Regrind lvl4
: 20% (0-80%)
(only when GR selected)
Deviation alarm
: 25 %
Auto start
: NO / YES (not
visible
in
Color
mode)
Master reset
: NONE / ALARM / MATER / ALL
IP
: xxx . xxx . xxx . xxx
(not visible in Color mode)
Name
: xxxxxxxxxxxxxx
Start user
: Operator / Tooling / Supervisor
(not visible in Color mode)
Tooling passw.
: xxxx 1111
(not visible in Color mode)
Supervisor passw.
: xxxx 2222
(not visible in Color mode)
Date
: (dd / mm / yy)
(not visible in Color mode)
Time
: (hh / mm / ss)
(not visible in Color mode)
Configuration: Language
The standard language is English. On request also different languages are
available.
Configuration: Motor type
LT
is Low Torque motor and
HT
is High Torque motor (See Section 5 for more information)
L
Do not select HT motor if LT motor is connected.
Configuration: Cylinder type
Type of feeding cylinder / feed screw (see Section 5 for more information)
Configuration: Material type
The type of material, normal granules (NG) or micro granules (MG).
(See Section 5 for more information)
Configuration: Calibration Setpoint
The maximum allowed deviation from the Calibration Setpoint can be adjusted in this
parameter. (For more information see Section 7.6)
Configuration: Control mode
(GRAVI) Gravimetric mode (See Section 7.5) or (RPM) Volumetric mode
Configuration: Input mode
Type of input signal. (Relay, Timer)
15 Dual Feed TrueFeed Manual
Содержание TrueFeed
Страница 4: ......
Страница 41: ...APPENDIX A TrueFeed Print view INSIDE VIEW OF THE CABINET 37 Dual Feed TrueFeed Manual...
Страница 42: ...APPENDIX B TrueFeed Wiring diagram 38 Dual Feed TrueFeed Manual Only with Dual TrueFeed...
Страница 44: ...APPENDIX D TrueFeed General Dimensions 40 Dual Feed TrueFeed Manual...