37
COMUNELLO
®Copyright 2019 - All rights reserved
ENGLISH
EXTENDED
MENU 2
• Press the SELECT button and scroll the LED menu until
you reach the LEV LED;
• Press SET twice to access the EXTENDED menu 2.
il LED della funzione LEV LAMPEGGIA con questa frequenza:
LIVEL 2 - EXTENDED MENU 2
LED
FUNCTION
DESCRIPTION
LED ON
LED OFF
DEFAULT
L1
BRAKE
Enabling of the electronic
brake
Always enabled
Always enabled
L2
STEP BY STEP 1
Step-By-Step logic
Open-Stop-Close-Stop (It DOESN'T close after the pause
time in a partial opening phase)
Disabled function
L3
ALWAYS CLOSE
Enables the sending of a
CLOSE command when the
power is turned on again
Enabled function
Disabled function
L4
FOLLOW ME
The motor automatically
closes in 5 sec after passing
through DS1 photocell
Enabled function
Disabled function
L5
PEDESTRIAN TIME
Storage of motor no.1 partial
stroke with slowdowns
Partial stroke of motor no.1 stored
10 sec., without slowdowns
L6
2°CH MONOSTABLE /
BISTABLE/TIMED MONO.
Setting the aux. relay of the
2°CH as Bistable / Monosta-
ble /Temporised monostable
Bistable command
Temporized 3 min.
Monostable command
(impulsive)
L7
REMOTELY PROGRAMMING
Enable the remote control
memory function without
acting on the control unit
Enabled function
Disabled function
Table 4
The fourth and last menu is defined as EXTENDED 3 and to access the programmable functions follow the instructions given in Table 5:
EXTENDED
MENU 3
• Press the SELECT button and scroll the LED menu until
you reach the LEV LED;
• Press SET 3 times to access the EXTENDED menu 3.
The LED of the LEV function FLASHES with this frequency
LIVEL 3 - EXTENDED MENU 3
LED
FUNCTION
DESCRIPTION
LED ON
LED OFF
DEFAULT
L1
SOFT STOP
Setting of gradual slowdown
at the end of the movement
Enabled function
Disabled function
L2
SOFT START
Setting of gradual slowdown
at the beginning of the
movement
Enabled function
Disabled function
L3
RELEASE STROKE MAX
FORCE/ RELEASE STROKE
Activation of the push in ope-
ning for electric lock release
Enabled function at the max
FORCE
Enabled function - FORCE
trimmer
Disabled function
L4
SLAM LOCK MAX FORCE /
SLAM LOCK
Activation of the push in clo-
sing for electric lock release
Enabled function at the max
FORCE
Enabled function - FORCE
trimmer
Disabled function
L5
ELS / CMD PED
Activation of the electric lock
as PPED input
Enabled function
Disabled function
L6
LAMP / L.CORT L.SPIA /
LAMP L.CORTESIA
Flashing light set as pilot light
or courtesy light
Flash.
→
Courtesy light
Flash.
→
court. light.; Pilot
light
→
Flash.
Flashing light
L7
PRELAMP / LAMP IN PAUSA
Activation of the pre-flash for
3 s. before the CLOSE cycle /
Flashing in pause time
Preflash in CLOSE
Fllash in pause time
Disabled function
Table 5
ATTENTION:
The control unit allows to be programmed if all the safety devices (N.C. inputs on terminals) grant a contact closed.
FOTO + Photocell control and power supply
LAMP 24V
Signal light output 24Vac
GND
Common GND input
DS2
Safety device input 2 (NC)
DS1
Safety device input 1 (NC)
STOP 8K2
Block / 8K2 input
GND
Common GND input
P PED: Ingresso Puls. Pedestrian/Single Door/open button input
(NO)
PP:
Open-close/close command button input (NO)
ELS +
Electric lock 24Vdc
ELS -
Electric lock output -
24V 5W Services output (+24Vdc)
GND:
Common GND input
SPIA+24V LED:
Output indicator lamp (+24 V / 4 W)
ANT-:
Chassis ground input (sheath)
ANT+:
Antenna hot pin input
CN3:
ENC1 +: Motor 1 Encoder power supply input
7
DETAILED DESCRIPTION OF ALL
FUNCTIONS
7.1 ELECTRICAL CONNECTIONS
L:
230 V~ Line input (Phase)
N:
230 V~ Line input(Neutral)
LAMP 230~:
Flashing Light Output 1 (230 V~ Neutral)
LAMP 230~:
Flashing Light Output 1 (230 V~ Phase)
MOT1 OPEN:
Operator 1 opening output
MOT1 COM:
Operator 1 output common
MOT1 CLOSE:
Operator 1 closing output.
MOT2 OPEN2:
Operator 2 opening output
MOT2 COM2:
Operator 2 output common
MOT2 CLOSE2:
Operator 2 closing output
CN2:
2nd CH: Aux Radio CH Output (Free Contact max load 30V DC 1A)
2nd CH: Aux Radio CH Output (Free Contact max load 30V DC 1A)