SLM-5650B Satellite Modem
Revision 2
Appendix C
C–53
MN-SLM-5650B
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to
Query
AUPC Maximum
Power Level
AMX=
5 bytes
Command or Query.
Maximum Tx Output power level, where:
s = sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm
Example: AMX = -13.4
AMX=
AMX?
AMX*
AMX#
AMX?
AMX=sxx.x
(see Description of
Arguments)
AUPC Nominal
Power Level
ANP=
5 bytes
Command or Query.
Nominal Tx Output power level, where:
s = sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm
Example: ANP = -13.4
ANP=
ANP?
ANP*
ANP#
ANP?
ANP=sxx.x
(see Description of
Arguments)
ASYNC ESC Rx
Baud Rate
ARB=
1 byte
Command or Query.
Baud Rate, where:
0 = 110
1 = 150
2 = 300
3 = 600
4 = 1200
5 = 2400
6 = 4800
7 = 9600
8 = 19200
9 = 38400
Example: ARB = 0 (sets the ASYNC ESC Rx Baud Rate to 110
Baud)
ARB=
ARB?
ARB*
ARB#
ARB?
ARB=x
(see Description of
Arguments)
Содержание SLM-5650B
Страница 58: ...SLM 5650B Satellite Modem Revision 2 Installation 2 8 MN SLM 5650B BLANK PAGE ...
Страница 142: ...SLM 5650B Satellite Modem Revision 2 Ethernet Based Management 6 12 MN SLM 5650B BLANK PAGE ...
Страница 280: ...SLM 5650B Satellite Modem Revision 2 TRANSEC Module HTTPS Interface 10 24 MN SLM 5650B BLANK PAGE ...
Страница 328: ...SLM 5650B Satellite Modem Revision 2 Appendix B B 16 MN SLM 5650B BLANK PAGE ...
Страница 394: ...SLM 5650B Satellite Modem Revision 2 Appendix C C 66 MN SLM 5650B BLANK PAGE ...
Страница 411: ......
Страница 412: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...