Front Panel Operation
Revision 4
5–21
ConvX LNA: Calibr (Calibrate Reference Current)
ConvX LNA Ref = 400.0 mA
Calibrate: No Yes (◄ ► E)
On the bottom line
, use the
◄ ►
arrow keys to select
No
or
Yes
, and then press
ENTER
. If you
select
Yes
and the LNA successfully calibrates, the current value appears on the top line of the
screen (e.g.,
400.0 mA
).
If calibration fails, however, the error message “
Calibration failed. Out of
Range.
” Displays, an the MBT-500 returns you to the previous menu. You will also observe,
once the previous menu re-displays, that no value appears on the top line for the reference
current (e.g.,
N/A
):
ConvX LNA Ref = N/A
Calibrate: No Yes (◄ ► E)
ConvX LNA: (Window) Enable
ConvX LNA Window:
Disable Enable (◄ ► E)
On the bottom line
, use the
◄ ►
arrow keys to
Disable
or
Enable
LNA alarms/faults
handling, and then press
ENTER
.
ConvX LNA: (Window) Range
ConvX LNA Range:
20%
On the bottom line
, use the
▼
▲
arrow keys to select a range percentage from
20%
to
50%
,
and then press
ENTER
.
5.2.6
SELECT: Test Menu Branch
TEST: Lamptest
Press
ENTER
to begin the diagnostics run on the front panel Light-Emitting Diode arrays and
Vacuum Fluorescent Display. The
Side A
and
Side B
LEDs will cycle, and the VFD will briefly
generate a test pattern.
Once the test has run, press
CLEAR
to return to the
SELECT:
(Main) menu.
Содержание MBT-5000
Страница 16: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Preface Revision 4 xvi Notes...
Страница 24: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Introduction Revision 4 1 8 Notes...
Страница 76: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Front Panel Operation Revision 4 5 22 Notes...
Страница 100: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Ethernet based Remote Product Management Revision 4 6 24 Notes...
Страница 124: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Serial based Remote Product Management Revision 4 7 24 Notes...
Страница 132: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix A Revision 4 A 8 Notes...
Страница 136: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix B Revision 4 B 4 Notes...
Страница 137: ......
Страница 138: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...