MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Serial-based Remote Product Management
Revision 4
7–19
7.3.2
Block Converter (BUC / BDC) Remote Commands and Queries
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(Note that all arguments are ASCII numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
Attenuation
Offset
AOF=
5 bytes
Command or Query.
Note:
Command is only for the offline converter in a redundancy mode. The valid range is -3.00 to
+3.00 dB.
Additionally, if the online converter attenuation is set to one extreme or the other, that value
becomes the new limiting factor. For example, if the attenuation is set to 19dB, the only
allowable offset will be -3 dB to +1 dB.
Default Value:
00.00
Example:
<2/AOF=+2.25’cr’
>0002/AOF=’cr’’lf’
AOF=
AOF?
AOF*
AOF?
AOF=+x.xx
or
AOF=-x.xx
(Same format as
Command
arguments)
Attenuation
ATT=
5 bytes,
Command or Query.
Valid attenuation level (00.00 to 50.00 for X-Band BUC units, 00.00 to 20.00 for all other), in dB,
in 0.25 dB steps as factory default.
Default Value:
00.00
Example:
<2/ATT=12.25’cr’
>0002/ATT=’cr’’lf’
Note:
Attenuation cannot be changed for the offline unit when in redundancy mode.
ATT=
ATT?
ATT*
ATT?
ATT=xx.xx
(Same format as
Command
arguments)
Calibrate LNA
Current
(BDC only)
CLC=
none
Command or Query.
Stores t he v alue of t he LN A C urrent S upply (i n m A) as a ref erence p oint. The LN A c urrent
alarm/fault point is then based on this point
the LCW setting.
Note:
This command will return a mode error if the LCS output has not been enabled first. It will
return 000.0 if the converter has never been calibrated.
Example:
<1/CLC=’cr’
>0001/CLC=’cr’’lf’
The CLC query will return the value that was stored during the LNA current calibration.
Example:
<1/CLC?’cr’
>0001/CLC=xxx.x
(where xxx.x is calibrated LNA current value in mA)
CLC=
CLC?
CLC*
CLC?
CLC=xxx.x
(see Description
of Arguments)
Содержание MBT-5000
Страница 16: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Preface Revision 4 xvi Notes...
Страница 24: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Introduction Revision 4 1 8 Notes...
Страница 76: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Front Panel Operation Revision 4 5 22 Notes...
Страница 100: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Ethernet based Remote Product Management Revision 4 6 24 Notes...
Страница 124: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Serial based Remote Product Management Revision 4 7 24 Notes...
Страница 132: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix A Revision 4 A 8 Notes...
Страница 136: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix B Revision 4 B 4 Notes...
Страница 137: ......
Страница 138: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...