![Comtech EF Data MBT-5000 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/comtech-ef-data/mbt-5000/mbt-5000_users-installation-and-operation-manual_2648432061.webp)
MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Front Panel Operation
Revision 4
5–7
Serial Config: Address
Remote Address: 0001
(◄ ► ▲ ▼ E)
The valid range of addresses is from 1 to 9997. Use the
◄ ►
arrow keys to select the digit to
edit, and then use the
▼
▲
arrow keys to change the value of that digit. Press
ENTER
when
done.
Serial Config: Baudrate
Local M&C Bus Baud Rate:
19200 Baud (▲ ▼ E)
To set the baud rate of the remote M&C bus connection between the unit and the user PC:
Use the
▲▼
arrow keys to select
2400
,
4800
,
9600
,
19200
, and
38400
. Press
ENTER
when
done.
The asynchronous character format is FIXED at 8 data bits, 1 stop bit, no parity
(8-N-1).
5.2.2.1.3
Remote Control: Ethernet
Ethernet Config: Gateway
Address MAC SNMP (◄ ► E)
Use the
◄ ►
arrow keys to select the parameter to configure –
Gateway
,
Address
,
MAC
, or
SNMP
– then press
ENTER
.
Ethernet Config: Gateway
Ethernet IP Gateway:
192.168.001.002 (◄ ► ▲ ▼)
To edit the IP Gateway Address for the Ethernet M&C port for this unit, use the
◄ ►
arrow
keys to first select the digit to edit, and then use the
▼
▲
arrow keys to edit the value of
that digit. Press
ENTER
when done.
Ethernet Config: Address
Ether IP Address/Range:
192.168.001.002/24(◄ ►▲ ▼)
To edit the IP Address and Range for the Ethernet M&C port for this unit, use the
◄ ►
arrow keys to first select the digit to edit, and then use the
▼
▲
arrow keys to edit the value
of that digit. Press
ENTER
when done.
Содержание MBT-5000
Страница 16: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Preface Revision 4 xvi Notes...
Страница 24: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Introduction Revision 4 1 8 Notes...
Страница 76: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Front Panel Operation Revision 4 5 22 Notes...
Страница 100: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Ethernet based Remote Product Management Revision 4 6 24 Notes...
Страница 124: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Serial based Remote Product Management Revision 4 7 24 Notes...
Страница 132: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix A Revision 4 A 8 Notes...
Страница 136: ...MBT 5000 L Band Up Down Converter System MN MBT5000 Appendix B Revision 4 B 4 Notes...
Страница 137: ......
Страница 138: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...