MBT-4000B Multi-Band Transceiver System
Revision 1
Appendix A
MN/MBT4000B.IOM
A–4
A.2.3 Informational Events
Informational Events are operation conditions which may be important, but are not
considered improper operation and will not cause a converter to mute.
Table A-4. MBT-4000B Informational Events
Mnemonic
Mute
Description
LOG CLR
None
The Event LOG Queue was cleared in response to receipt of a CAA command.
PWR OFF
None
Power off was detected.
PWR ON
None
Power on was detected.
Table A-5. BUC-4000 Informational Events
Mnemonic
Description
LOG CLR
The Event LOG Queue was cleared in response to receiving a CAA command.
PWR OFF
Power off was detected.
PWR ON
Power on was detected.