MBT-4000B Multi-Band Transceiver System
Revision 1
External Connectors
MN/MBT4000B.IOM
3–7
3.2.1.9 J6 | COMM (BUC-4000 ONLY)
Use the
J6 | COMM
15-pin circular connector, located on the BUC-4000 Block
Up Converter Module, to connect the module, via the 15-15 Power & Signal
Harness (CEFD P/N CA/WR10963-1), to the MBT-4000B Base Module
J3 |
UNIT 1 COMM
connector. See
Figure 3-3
.
Table 3-6. J6 | COMM (J6) Connector Pinouts
Pin
Signal
A
SUM FLT
B
TxD BXC
C
Tx+ BXC
D
GND
E
+7.5V
F
+7.5V
G
+15V
H
GND
J
Rx+ BXC
K
Rx- BXC
L
Tx- BXC
M
RxD BXC
N
SPARE
P
10 MHz REF
R
SPARE
NOTE – Mating Connector:
CEFD P/N CN/8LT5-15B15PN
( Souriau 8LT5-15B15PN / Amphenol MS27467T15B15P)