MBT-4000B Multi-Band Transceiver System
Revision 1
Appendix A
MN/MBT4000B.IOM
A–2
A.2
Faults/Events
There are three types of Faults/Events that may occur and be recorded in the event log of the
MBT-4000B or BUC-4000:
•
Summary Faults
•
Configurable Summary Faults
•
Informational Events
.
Each of these are described in further detail in the next
subsections;
Tables B1
through
B6
list possible
Fault/Event messages where applicable. An example of
a faulted system is shown in
Figure A-2
; here, Unit 2
has faulted.
Figure A-2. Faulted System Example
A.2.1 Summary Faults
Summary Faults indicate improper operation. When a Summary Fault condition occurs, the
Summary Fault Relay will be de-energized. If a Summary Fault occurs on a converter, it will
mute. If a Summary Fault occurs on the base unit, the converter will be muted according to the
specific error. If a Summary Fault occurs on the online unit of a redundant pair, the offline unit
will detect the fault and assume online state. In all cases, a corresponding event message will be
added to the event log.
Table A-1. MBT-4000B Summary Faults
Mnemonic
Mute
Description
15V PS1
All
The 15 volt power supply is out of tolerance.
28V PS1
All
The 28 volt power supply is out of tolerance.
5VT PS1
All
The 5 volt power supply is out of tolerance.
7V5 PS1
All
The 7.5 volt power supply is out of tolerance.
IIC BUS
All
Unable to communication via the internal high speed communication bus
Table A-2. BUC-4000 Summary Faults
Mnemonic
Description
15V SUP
The 15 volt power supply is out of tolerance.
5VT SUP
The 5 volt power supply is out of tolerance.
7V5 SUP
The 7.5 volt power supply is out of tolerance.
OVR TMP
The maximum operating temperature has been exceeded.
PLL LD
The PLL has lost lock.
Содержание MBT-4000B
Страница 14: ...MBT 4000B Multi Band Transceiver System Revision 1 Preface MN MBT4000B IOM xiv Notes...
Страница 20: ...MBT 4000 Multi Band Transceiver System Revision 1 Introduction MN MBT4000B IOM 1 6 Notes...
Страница 38: ...MBT 4000B Multi Band Transceiver System Revision 1 System Operating Parameters MN MBT4000B IOM 4 6 Notes...
Страница 50: ...MBT 4000B Multi band Transceiver System Revision 1 Updating Firmware MN MBT4000B IOM 5 12 Notes...
Страница 84: ...MBT 4000B Multi Band Transceiver System Revision 1 Appendix B MN MBT4000B IOM B 8 Notes...
Страница 85: ......
Страница 86: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...