A.2.2 Configurable Summary Faults
Configurable Summary Faults operate the same as Summary Faults, except Configurable
Summary Faults may be enabled or disabled using remote commands.
Table A-3. MBT-4000B Configurable Summary Faults
Mnemonic
Mute
Description
AUXCOM1
Slot 1 The IO1A/FAULT input (AUX COMM 1) indicates a fault. Monitoring for this fault is
enabled using the EAM command.
LNACUR2
Slot 2
The +17 V nominal bias tee provided LNB power supply current has exceeded the
maximum limit of 450 mA and has been disabled. The LNB power supply – and thus
this fault – is enabled using the LCS command.
This fault is cleared by a LCS command or power cycle.
LNAWIN2
Slot 2
The +17 V nominal bias tee provided LNB power supply current is outside the
programmed window. (The power supply is not disabled in response to this fault.). LNB
current window monitoring is configured and enabled using the LCS, CLC and LCW
commands.
This fault is cleared by an LCS command, CLC command, LCW command or power
cycle.
REF LD
All
The External Reference Monitor has lost lock with the external reference signal. The
attached converter has been muted. Monitoring for this fault is enabled using the XRF
command.
This fault is cleared when lock has been regained.
Содержание MBT-4000B
Страница 14: ...MBT 4000B Multi Band Transceiver System Revision 1 Preface MN MBT4000B IOM xiv Notes...
Страница 20: ...MBT 4000 Multi Band Transceiver System Revision 1 Introduction MN MBT4000B IOM 1 6 Notes...
Страница 38: ...MBT 4000B Multi Band Transceiver System Revision 1 System Operating Parameters MN MBT4000B IOM 4 6 Notes...
Страница 50: ...MBT 4000B Multi band Transceiver System Revision 1 Updating Firmware MN MBT4000B IOM 5 12 Notes...
Страница 84: ...MBT 4000B Multi Band Transceiver System Revision 1 Appendix B MN MBT4000B IOM B 8 Notes...
Страница 85: ......
Страница 86: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...