MBT-4000 Multi-Band Transceiver System
Revision 1
Introduction
MN/MBT4000B.IOM
1–4
1.4
Summary of Specifications
1.4.1
Environmental & Physical
Temperature
ODU: BUC-4000
Operating
-40º to 122ºF (-40º to 50ºC)
Non-operating
-58º to 167ºF (-50º to 75ºC)
Operational Humidity
5 to 95% non-condensing
Operational Altitude
10,000 ft above sea level
Prime Power
ODU: MBT-4000B
90 to 260 VAC, 47 to 63 Hz
Dimensions (excluding connectors)
See Figure 1-4
1.4.2
BUC-4000 Block Up Converter ODU
Input Frequency Range
950 to 2000 MHz, 125 kHz steps
1 kHz (optional)
Output Frequency
(by model)
BUC-4000C
5860 to 6650 MHz
BUC-4000X
7900 to 8400 MHz
BUC-4000Ku
13.75 to 14.50 GHz
BUC-4000Ka
30.00 to 31.00 GHz
27.50 to 28.50 GHz (optional)
28.50 to 29.50 GHz (optional)
29.50 to 30.10 GHz (optional)
Input/Output Impedance
50
Ω
Input Return Loss
15 dB minimum
Output Return Loss
18 dB minimum
Input Connector
Type ‘N’ Female
Output Connector
Type ‘N’ Female (C-, X-, and Ku-Band)
Gain
15 dB nominal at minimum attenuation
User Attenuation Range
0 to 10 dB
Output Power, P1dB
+10 dBm minimum
Third Order Intercept
+20 dBm minimum
Spurious
Carrier Related
-60 dBc
Non-Carrier Related
-60 dBm
External Reference
Input, either 5 MHz or 10 MHz
±
5 dBm (optional)
Содержание MBT-4000B
Страница 14: ...MBT 4000B Multi Band Transceiver System Revision 1 Preface MN MBT4000B IOM xiv Notes...
Страница 20: ...MBT 4000 Multi Band Transceiver System Revision 1 Introduction MN MBT4000B IOM 1 6 Notes...
Страница 38: ...MBT 4000B Multi Band Transceiver System Revision 1 System Operating Parameters MN MBT4000B IOM 4 6 Notes...
Страница 50: ...MBT 4000B Multi band Transceiver System Revision 1 Updating Firmware MN MBT4000B IOM 5 12 Notes...
Страница 84: ...MBT 4000B Multi Band Transceiver System Revision 1 Appendix B MN MBT4000B IOM B 8 Notes...
Страница 85: ......
Страница 86: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...