1.5.3 CRS-280 and CRS-280L IF Switch Specifications
Characteristic
Requirement
CRS-280 (70/140MHz)
CRS-280L (L-Band)
Tx/Rx Operating Freq
50 to 180 MHz
950 to 1950 MHz
Tx / Rx Connectors
BNC female
N-Type female (50
Ω
)
Return Loss
18 dB return loss into 75
Ω
(50
Ω
optional)
15 dB return loss into 50
Ω
Transmit IF Loss/Flatness
•
Tx In To Tx Uplink Out
•
BU In To Any Uplink Out
< 1.5 dB over operating freq
< 1.5 dB over operating freq
< 0.8 dB/0.5 dB over operating freq
< 2.5 dB/1.0 dB over operating freq
Receive IF Loss/Flatness
•
Rx Downlink In To Rx Out
•
Any Downlink In To BU Out
< 5 dB over operating freq
< 5 dB over operating freq
< 4.0 dB/0.5 dB over operating freq
< 5.5 dB/1.0 dB over operating freq
Tx to Tx Channel Isolation
> 50 dB
> 70 dB
Rx to Rx Channel Isolation
> 50 dB
> 70 dB
Tx to Rx Channel Isolation
> 60 dB
> 90 dB
Powering of IF Switch
From the CRS-300 chassis
100 to 240 VAC 50/60 Hz (25W)
Power Supply
90-264 VAC, 50/60 Hz (25 W)
90-264 VAC
Fuse
Dimensional Envelope
(Rack Mount 4RU)
19W x 2.5D x 7H inches (48.26W x 6.35 x 18H cm)
Weight
< 10 lbs (< 4.54 kg)
< 25 lbs (11.3 kg)
1.5.4 CRS-350 ESC Switch Specifications
Characteristic
Requirement
User Data Interfaces
(1) DB-25M Connector – ESC, overhead signals
(1) DB-15F Connector – IDR Alarms
(1) DB-9F Connector – Audio
Power
From CRS-300
Dimensional Envelope
(Rack Mount 4U)
19W x 4.0D x 7H inches
(48.26W x 27.5D x 18H cm)
Weight
5 lbs (2.2 kg)
Содержание CRS-300
Страница 16: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Table of Contents Revision 19 xvi BLANK PAGE ...
Страница 24: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Preface Revision 19 xxiv Notes ...
Страница 47: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Introduction Revision 19 1 23 Figure 1 30 CRS 350 ESC Switch ...
Страница 48: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Introduction Revision 19 1 24 Notes ...
Страница 72: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Switch Connectors and Pinouts Revision 19 3 20 Notes ...
Страница 82: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 10 Notes ...
Страница 88: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 16 Notes ...
Страница 112: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 40 Notes ...
Страница 122: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 50 Notes ...
Страница 138: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 66 Notes ...
Страница 144: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 72 Notes ...
Страница 156: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 84 Notes ...
Страница 162: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Cables and Connections Revision 19 4 90 Notes ...
Страница 192: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Modem RMI TMI and Switch Configuration Revision 19 5 30 Notes ...
Страница 237: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Appendix A Revision 19 A 7 BLANK PAGE ...
Страница 244: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Appendix A Revision 19 A 14 Notes ...
Страница 282: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Appendix B Revision 19 B 38 Notes ...
Страница 292: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Appendix C Revision 19 C 10 BLANK PAGE ...
Страница 296: ...CRS 300 1 10 Redundancy Switch MN CRS300 IOM Appendix C Revision 19 C 14 Notes ...
Страница 297: ......
Страница 298: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...