CRS-150 1:1 Redundancy Switch
Revision 2
Connector Pinouts
MN/CRS150.IOM
3–5
3.2.2.2 Data Interface Connector, DB-25F
The 25-pin ‘D’ Type female (DB-25F) Data Interface connector
connects to customer’s terrestrial equipment. It conforms to the
EIA-530 pinout, which allows for connection of different electrical
standards, including EIA-422, V.35, and EIA-232. A shielded 25-pin ‘D’ type connection provides
a very solid solution to EMC problems, unlike the sometimes-used V.35 Winchester connector.
It is the user’s responsibility to provide the appropriate cables to connect to
this EIA-530 connector.
Data Interface Connector (DB-25F)
Pin #
Generic Signal Description
Direction
EIA-422
EIA-530
LVDS
V.35
EIA-232
Circuit #
2
TX Data A
DTE to Modem
SD A
SD A
BA
103
14
TX Data B
DTE to Modem
SD B
SD B
--
103
24
TX Clock A
DTE to Modem
TT A
SCTE A
DA
113
11
TX Clock B
DTE to Modem
TT B
SCTE B
--
113
15
INT TX Clock A
Modem to DTE
ST A
SCT A
DB
114
12
INT TX Clock B
Modem to DTE
ST B
SCT B
--
114
3
RX Data A
Modem to DTE
RD A
RD A
BB
104
16
RX Data B
Modem to DTE
RD B
RD B
--
104
17
RX Clock A
Modem to DTE
RT A
SCR A
DD
115
9
RX Clock B
Modem to DTE
RT B
SCR B
--
115
8
Receiver Ready A
Modem to DTE
RR A
RLSD *
CF
109
10
Receiver Ready B
Modem to DTE
RR B
--
--
109
23
External Carrier Off
(EIA-232 ‘1' or TTL ‘low’ )
DTE to Modem
--
--
--
--
7 Signal
Ground
--
SG
SG
AB
102
1 Shield
--
Shield
FG
AN
101
Notes:
1.
Receiver Ready is an EIA-232 -level control signal on a V.35 interface.
2.
DO NOT connect signals to pins which are not shown - these pins are reserved for
use by the redundancy system.
3.
‘B’ signal lines are not used for EIA-232 applications.
4.
For X.21 operation, use the EIA-422 pins, but ignore RX Clock if the Modem is DTE,
and ignore TX clocks if the Modem is DCE.
5.
For IDR operation using G.703, this primary interface becomes the 8 kbps EIA-422
overhead channel.
Содержание CRS-150
Страница 14: ...CRS 150 1 1 Redundancy Switch Revision 2 Preface MN CRS150 IOM xiv Notes...
Страница 22: ...CRS 150 1 1 Redundancy Switch Revision 2 Introduction MN CRS150 IOM 1 8 Notes...
Страница 42: ...CRS 150 1 1 Redundancy Switch Revision 2 Connector Pinouts MN CRS150 IOM 3 18 Notes...
Страница 74: ...CRS 150 1 1 Redundancy Switch Revision 2 Cable Drawings MN CRS150 IOM A 12 Notes...
Страница 76: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...