CRS-150 1:1 Redundancy Switch
Revision 2
Connector Pinouts
MN/CRS150.IOM
3–8
3.2.3 Front Panel Utility Connectors
3.2.3.1 Ext Ref, 50
Ω
BNC
This is 50
Ω
BNC female connector is used for operating an external station reference. It
requires an EIA-422 compatible level, so this unbalanced input should have a zero volt
(0V) offset and a swing of at least
±
2V into the 120
Ω
termination provided.
3.2.3.2 IDR Alarms Connector, DB-15F
The 15-pin Type ‘D’ female (DB-15F) IDR Alarms interface connection
provides four Form-C backward alarm outputs specified by Intelsat.
IDR Alarms Connector (DB-15F)
Pin #
Signal Function
Name
2
9
1
Backward Alarm 1 is active
Backward Alarm 1 is not active
BA-1-NO
BA-1-COM
BA-1-NC
10 TBD
MON-A
4
11
3
Backward Alarm 2 is active
Backward Alarm 2 is not active
BA-2-NO
BA-2-COM
BA-2-NC
6
13
5
Backward Alarm 3 is active
Backward Alarm 3 is not active
BA-3-NO
BA-3-COM
BA-3-NC
14 TBD
MON-B
8
15
7
Backward Alarm 4 is active
Backward Alarm 4 is not active
BA-4-NO
BA-4-COM
BA-4-NC
12 Ground
GND
3.2.4 Front Panel Power Connections – Aux DC Inputs
The front panel of the CRS-150 incorporates two independent DC inputs (using 2.1
mm sockets, with the outer conductor grounded). Comtech EF Data can supply the
appropriate AC/DC supply, complete with IEC power input connector (Part number
PS/AC18W01P01).
For more information about Comtech EF Data accessories that make use of this interface, see
Chapter 1. INTRODUCTION
.
Содержание CRS-150
Страница 14: ...CRS 150 1 1 Redundancy Switch Revision 2 Preface MN CRS150 IOM xiv Notes...
Страница 22: ...CRS 150 1 1 Redundancy Switch Revision 2 Introduction MN CRS150 IOM 1 8 Notes...
Страница 42: ...CRS 150 1 1 Redundancy Switch Revision 2 Connector Pinouts MN CRS150 IOM 3 18 Notes...
Страница 74: ...CRS 150 1 1 Redundancy Switch Revision 2 Cable Drawings MN CRS150 IOM A 12 Notes...
Страница 76: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...