CRS-150 1:1 Redundancy Switch
Revision 2
Cables and Connections
MN/CRS150.IOM
4–2
4.2
Cabling to the CDM-600
Examples for connecting a pair of CDM-600 modems together with the CRS-150 are provided in
this section. Once all connections have been made, refer to
Chapter 5. MODEM AND SWITCH
CONFIGURATION
in this manual – as well as the
CDM-600 Satellite Modem Installation and
Operation Manual –
to enable 1:1 operation.
The following cables, purchased separately unless noted otherwise, are utilized with all possible
CDM-600 data interface configurations:
CRS-150
Æ
CDM-600 1:1 Redundancy – Interface Cabling Reference
CEFD Part #
Description
Used for:
Ch. 4 Fig.
CA/USB-AM/BM-3 Control Cable, USB Type ‘B’ to USB Type ‘A’ (3’)
**
Modem
Æ
Switch Control
4-1
CA/WR9040-4
Data Cable, DB-25F
Æ
DB-25F (4’)
Modem
Æ
Switch Overhead
4-12
CA/WR9378-4
Data Cable, DB-9M
Æ
DB-9M (4’)
Modem
Æ
Switch Audio
4-13
CA/WR9563-4
Data Cable, DB-15M
Æ
DB-15M (4’)
Modem
Æ
Switch G.703
4-8, 4-9,
4-10, 4-11
CA/WR9564-4
Data Cable, DB-15M
Æ
DB-15M (4’)
Modem
Æ
Switch IDR Alarms
4-3
PL/0813-4
Coax Cable, Type ‘BNC’ 75
Ω
(4’)
Modem
Æ
Switch Ext Ref
4-4
PL/0946-1
IF (Tx/Rx) Coax Cable, Type ‘BNC’ 50
Ω
(4’)
Modem
Æ
Switch IF Interface
4-2
PL/6233
Data/Control Cable, Universal, DB-25M
Æ
DB-25M (4’)
Modem
Æ
Switch Universal Data
4-6, 4-7
When connecting the Control cable between the CRS-150 and the modems,
ensure that screw locks on the ‘D’ type connectors are securely fastened. This
will prevent the accidental unmating of the cable, particularly when a standby unit
is being removed or replaced.
** Although the Auxiliary Serial ports on the CRS-150 and CDM-600 use USB
connectors, the signals are
not
USB compatible.
DO NOT
use these cables to
connect any of these ports to the USB port of a PC or other computing device.
To properly connect a CDM-600 modem pair together with the CRS-150 1:1 Redundancy Switch,
it is essential to ensure that all cable connections, particularly the control and IF (both Rx and Tx)
connections, are made correctly:
For
Refer to:
Modem
Æ
Switch Control Connections
Sect. 4.2.2
Modem
Æ
Switch IF Connections
Sect. 4.2.3
Modem
Æ
Switch Utility Connections
Sect. 4.2.4
Modem
Æ
Switch Data Interface Connections
Sect. 4.2.5
4.2.1.1 CRS-150 Accessories
Additional accessory equipment that may be ordered includes:
•
CIC-20 (CEFD P/N PL/9459-1) HSSI to LVDS Interface Converter
•
CIC-35 (CEFD P/N PL/10335-1) ASI to LVDS Interface Converter
•
CEFD P/N PS/AC18W01P01 Auxiliary Power Supply for use with CIC-20 or CIC-35
•
CEFD P/N CA-0000268 DB-15F to RJ-48 Adapter (for Balanced G.703 E1/T1)
Содержание CRS-150
Страница 14: ...CRS 150 1 1 Redundancy Switch Revision 2 Preface MN CRS150 IOM xiv Notes...
Страница 22: ...CRS 150 1 1 Redundancy Switch Revision 2 Introduction MN CRS150 IOM 1 8 Notes...
Страница 42: ...CRS 150 1 1 Redundancy Switch Revision 2 Connector Pinouts MN CRS150 IOM 3 18 Notes...
Страница 74: ...CRS 150 1 1 Redundancy Switch Revision 2 Cable Drawings MN CRS150 IOM A 12 Notes...
Страница 76: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...