The RS232 port on the DH30 is a serial communications port used to control DH30
operations through an external device such as a PC or a control device. This section
describes the protocol and serial commands used to control the DH30.
The RS232 serial port runs at 9600 baud, no parity, eight data bits and one stop bit.
Serial commands to the DH30 can control the following types of operations: Hybrid
On/Off, Cuing, Recording, Monitor volume, Preset selection and Detection of an In-
coming Call.
Function
On/Off
Off
On
Cue Status
Cue Off
Cue On
Cue Toggle
Record Status
Record Off
Record On
Record Toggle
Monitor Volume Up*
Monitor Volume Down
*no value give
Current Preset
Select Preset 1
Select Preset 2
Select Preset 3
Incoming Call
Status Returned
0
1
2
3
Serial Command
TE<cr>
TE 0<cr>
TE 1<cr>
CUE<cr>
CUE 0<cr>
CUE 1<cr>
Cue 2<cr>
REC<cr>
REC 0<cr>
REC 1<cr>
REC 2<cr>
VOLUP<cr>
VOLDWN<cr>
PRESET<cr>
PRESET 1<cr>
PRESET 2<cr>
PRESET 3<cr>
N/A
Record-Ready
no
yes
no
yes
Returned Status
TE 0<cr> or TE1<cr>
TE O
TE 1
CUE 0 or CUE 1
CUE 0
CUE 1
CUE 0 or CUE 1
(toggled)
REC 0/1/2/3
(see note below)
VOLUP
VOLDWN
PRESET 1
PRESET 2
PRESET 3
RING
Recording
no
no
yes
yes
NOTE: The returned status is dependent on the current setting of the hybrid. See table below: