![Comrex DH30 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/comrex/dh30/dh30_product-manual_2648269029.webp)
DH30 Product Manual
29
Status Outputs:
Remotely check the status of the hybrid with the ON, OFF, CUE,
REC, send presence and caller presence status outputs. All status
outputs are open collector outputs rated at 40VDC and 50mA
maximum.
MONITOR OUTPUT: 1/4” stereo jack
tip=+phase, ring=-phase, sleeve=-phase
2W output into an 8 Ohm load
SEND INPUT: XLR female
Mic/Line selectable, -55 or 0dBu nominal, adjustable, balanced
bridging, 20k Ohm impedance, selectable 12VDC Phantom Power
CUE IN: XLR female
Mic/Line selectable, -55 or 0dBu nominal, adjustable, balanced
bridging, 20k Ohm impedance, selectable 12VDC Phantom Power
CALLER OUTPUT: XLR male
0dBu nominal, adjustable, balanced 50k Ohm impedance
AUX OUTPUT: XLR male
0dBu nominal, adjustable, balanced 50k Ohm impedance
TELCO LINE: RJ11 connector
POTS (plain old telephone service) line or analog extension from a
PBX or dry line (no DC offset voltage). A-Lead supervision provided
(see “Line Connector” pinout chart on page 32 for further details).
TELCO SET: RJ11 connector
A-Lead supervision provided (see “Set Connector” pinout chart on
page 32 for further details).
All measurements referenced at –15dBm level on the phone line.
FREQUENCY RESPONSE: +/- 1dB from 250Hz to 3.5kHz
DYNAMIC RANGE: >70dB
DISTORTION: <0.15%
t
elePhone
t
ranSmit