4.6.2
Diagnostic operations by Handset
The external handset permits to perform a deep diagnostic of the door controller:
-
Check of ALL the settings
-
Speed profiles check
-
Drive readings check
-
Check of ALL I/O
4.6.2.1
I/O diagnostic
Access to “Main Menu”
“Maintenance”
“MLC Monitor” and check the status of ALL inputs and
outputs of the door drive. When the signal is active, the correspondent signal description results
highlighted.
ATTENTION: in this menu the controller returns in Normal mode, and executes all the commands
coming from the Main Lift Controller.
The following table shows the I/O visualization:
INPUTS
OUTPUTS
DOC 5
FFC 39
DOS 17
DCC 3
AUXC 42
DCS 19
RSC 22
DTBC 41
RVS 1-2
RVC 23
EOC 40
AUXS 34-36
DETC 32
BUZS 21
- Table 21: I/O signals reported -
4.6.2.2
Profiles and measurements checks
Access to: “Main Menu”
“Maintenance”
“Monitor”. The “Monitor” menu permits to check the speed
profiles (speed reported in m/s), output power (in W) and output force (in N). By pressing OK button, it is
possible to access to the measurements table as reported below:
MEASUREMENTS
Column 1
Column 2
Last panels opening time (even if partial reopening)
Last panels closing time (even if partial reclosing)
Learned door space (including clutch movement)
Skate Space (set or measured)
Actual door position
Motor Type
Instantaneous motor current
Estimated motor temperature
Actual Closing force limit
% of battery charge (-- = battery not connected)
Mains voltage
- Table 22: measurements reported in the monitor menu table -
NOTE: the space measurements are calculated based on the encoder mounted on the motor. The absolute
precision is then influenced by all the transmission system tolerances.