6
Obstacle reversing
check in Inspection
mode
Put an obstacle at different points of the door access.
Press and keep pressed key
to perform a door
closing.
When the panels meet the obstacle, the door drive will
immediately reverse the movement starting the
reopening.
Release key
during the reopening movement and
wait until the door is completely opened.
In case it is necessary to configure reversing system,
please refer to the paragraph 5.2.1
Display visualization:
“CL” blinking
“IM” blinking
“OP” fixed or
“- -“ blinking
7
Detector check in
Inspection mode
Execute this step only if external optical detector, light
curtains or photocell are directly connected to the
CDD6, to the RVC input or to the X9 plug.
During the door closing, interrupt the light curtains and
check the immediate reopening of the door, until the
door is completely open.
Remove any obstacle from the detector activation zone,
and check the door closing until the door is completely
closed.
In case it is necessary to configure reversing system,
please refer to the paragraph 5.2.1.
In case it is necessary to configure input reversing,
please refer to the paragraph 5.2.15.1, 5.5.2, 5.5.3
Display visualization:
INSP. LED is ON
“CL” blinking
“IM” blinking.
“IM” fixed.
“CL” blinking
“CL” fixed