05, indicate a seek failure, as listed in Table 2-15C. When you combine
this information, you know that the diagnostics program was testing the
random-read functioning of the hard drive and received a seek failure.
The device is faulty and must be replaced.
Table 2-15A. SCSI Device Names
===========================================================================
65XX - XX
Hard Drive
66XX - XX
CD-ROM Drive
67XX - XX
Tape Drive
===========================================================================
Table 2-15B. SCSI Test Names
===========================================================================
XX00 - XX
ID
XX03 - XX
Power Check
XX05 - XX
Read
XX06 - XX
SA/Media
XX08 - XX
Controller
XX23 - XX
Random Read
XX28 - XX
Media load/unload
===========================================================================
Table 2-15C. SCSI Test Error Codes
===========================================================================
Error
Code
Description
Recommended Action
===========================================================================
XXXX - 02
Drive not installed
Check cable connections.
---------------------------------------------------------------------------
XXXX - 03
Media not in drive
Install DATA CD/write-enabled tape in
drive.
---------------------------------------------------------------------------
XXXX - 05
Seek failure
Replace the indicated device.
XXXX - 06
Drive timed out
XXXX - 07
Drive busy
XXXX - 08
Drive already reserved
XXXX - 09
Unknown
XXXX - 10
Unknown
XXXX - 11
Media soft error
XXXX - 12
Drive not ready
XXXX - 13
Media error
Содержание Prolinea 4100
Страница 92: ...7 Release the wires going to the power switch from the clamps on the base pan Figure 5 14...
Страница 94: ......
Страница 95: ......
Страница 112: ...8 Remove and retain the hard drive mounting bracket Figure 5 33...
Страница 148: ......
Страница 149: ...540 MB IDE Hard Drive Jumper Settings The jumper settings for the 540 MB IDE are shown in Figures 6 9 and 6 10...
Страница 150: ......
Страница 151: ...720 MB IDE Hard Drive Jumper Settings The jumper settings for the 720 MB IDE are shown in Figure 6 11...
Страница 152: ...1 GB IDE Hard Drive Jumper Settings The jumper settings for the 1 GB IDE are shown in Figure 6 12...
Страница 167: ......
Страница 168: ......
Страница 191: ...Table A 2 Mouse Pin Signal 1 Data 2 Unused 3 Ground 4 5 VDC 5 Clock 6 Unused...