o Hard drives
POST also detects the type of mass storage devices installed in the
computer. If POST finds an error in the system, an error condition is
indicated by an audible and/or visual message.
Power-on Self-Test Messages
An error message results if a problem is encountered during the Power-On
Self-Test utility. Table 2-1 lists the messages for POST, the audible
(beep) message, probable cause, and recommended action. The procedures
referenced under "Recommended Action" are described in Sections 2.3 and
2.4 of this chapter.
Table 2-1. Power-On Self-Test Messages
===========================================================================
Message
Beeps
Probable Cause
Recommended Action
===========================================================================
101 - ROM Error
1 Long,
System ROM checksum
1. Inspect the ROM
1 Short
placement.
2. Verify the
correct ROM.
3. Replace the ROM.
---------------------------------------------------------------------------
101 - I/0 ROM
None
Option ROM checksum
1. Inspect the ROM
Error
placement.
2. Verify the
correct ROM.
3. Replace the ROM.
---------------------------------------------------------------------------
102 - System
None
DMA, timers, etc.
Replace the system
Board Failure
board.
---------------------------------------------------------------------------
162 - System
2 Short
No diskette drive or
Run Computer Setup.
Options Error
mismatch in drive
type
---------------------------------------------------------------------------
162 - System
2 Short
Configuration
Run Computer Setup.
Options Not
incorrect
Set
---------------------------------------------------------------------------
163 - Time &
2 Short
Invalid time or date
Run Computer Setup.
Date Not Set
in configuration
memory
---------------------------------------------------------------------------
164 - Memory
2 Short
Configuration
Run Computer Setup.
Size Error
memory incorrect
---------------------------------------------------------------------------
174 - ISA
1 Short
Plug & Play ISA
Run the
Configuration/
board not found
Configuration and
Slot Mismatch
Diagnostics
Utilities.
---------------------------------------------------------------------------
175 - ISA
1 Short
Plug & Play ISA
Run the
Configuration/
board added,
Configuration
Slot Mismatch
configuration not
and Diagnostics
updated
Utilities.
Содержание Prolinea 4100
Страница 92: ...7 Release the wires going to the power switch from the clamps on the base pan Figure 5 14...
Страница 94: ......
Страница 95: ......
Страница 112: ...8 Remove and retain the hard drive mounting bracket Figure 5 33...
Страница 148: ......
Страница 149: ...540 MB IDE Hard Drive Jumper Settings The jumper settings for the 540 MB IDE are shown in Figures 6 9 and 6 10...
Страница 150: ......
Страница 151: ...720 MB IDE Hard Drive Jumper Settings The jumper settings for the 720 MB IDE are shown in Figure 6 11...
Страница 152: ...1 GB IDE Hard Drive Jumper Settings The jumper settings for the 1 GB IDE are shown in Figure 6 12...
Страница 167: ......
Страница 168: ......
Страница 191: ...Table A 2 Mouse Pin Signal 1 Data 2 Unused 3 Ground 4 5 VDC 5 Clock 6 Unused...