3-12
Diagnostic Tools
Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Beeps
Probable Source of
Problem
Action
1796-Drive Array - Array
Accelerator Not
Responding.
Array Accelerator is
temporarily disabled.
None
Array Accelerator is
defective or has been
removed.
1.
Check that the Array
Accelerator is
properly seated.
2.
Run the System
Configuration Utility
to re-configure the
Compaq IDA-2
without the Array
Accelerator.
1797-Drive Array - Array
Accelerator Read Error
Occurred.
Data in Array Accelerator
has been lost.
Array Accelerator is
disabled.
None
Hard parity error
while reading data
from posted writes
memory.
Enable Array
Accelerator.
1798-Drive Array - Array
Accelerator Write Error
Occurred.
Array Accelerator is
disabled.
None
Hard parity error
while writing data to
posted writes
memory.
Enable Array
Accelerator.
1799-Drive Array - Drive(s)
Disabled due to Array
Accelerator Data Loss.
Select "F1" to continue with
logical drives disabled.
Select "F2" to accept data
loss and to re-enable
logical drives.
None
Volume failed due to
loss of data in
posted-writes
memory.
Press F1 to continue with
logical drives disabled or
F2 to accept data loss
and re-enable logical
drive.
2L,2S
Power is cycled.
Temperature too hot.
Processor fan not
installed or spinning.
Check fans.
(Run System Configuration
Utility = "F10" key)
None
A configuration error
occurred during
POST.
Press F10 to run System
Configuration Utility.
(RESUME = "F1" KEY)
None
As indicated to
continue.
Press the F1 key.
Содержание ProLiant 4500 Servers