![Compaq ProLiant 4500 Servers Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/compaq/proliant-4500-servers/proliant-4500-servers_maintenance-and-service-manual_2646515037.webp)
3-4
Diagnostic Tools
Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Beeps
Probable Source of
Problem
Action
173- Slot ID
Mismatch
None
Board replaced, but
configuration not
updated.
Run the System
Configuration Utility and
correct.
174-
Configuration/Slot
Mismatch Device
Not Found
None
EISA or PCI board not
found.
Run the System
Configuration Utility and
correct.
175-
Configuration/Slot
Mismatch Device
Found
None
EISA or PCI board
added, configuration not
updated.
Run the System
Configuration Utility and
correct.
176-Slot with Not
Readable ID Yields
Valid ID
None
EISA or PCI board in slot
that should contain an
ISA board.
Run the System
Configuration Utility and
correct.
177-Configuration
Not Complete
None
Incomplete System
Configuration.
Run the System
Configuration Utility and
correct.
178-Processor
Configuration Invalid
None
Processor type or step
does not match
configuration memory.
Run the System
Configuration Utility and
correct.
179-System
Revision Mismatch
None
A board was installed
that has a different
revision date.
Run the System
Configuration Utility and
correct.
201-Memory Error
None
RAM failure.
Run Diagnostics.
203-Memory
Address Error
None
RAM failure.
Run Diagnostics.
205-Cache Memory
Error
Option-Cache
Memory Error
None
Cache memory error.
Option Cache Memory
Error.
Replace the processor
board in the slot
indicated.
Replace the option cache
board.
206-Cache
Controller Error
None
Cache controller failure.
Run Diagnostics.
Continued
Содержание ProLiant 4500 Servers
Страница 2: ...CHMP ...