3-8
Diagnostic Tools
Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Beeps
Probable Source of
Problem
Action
1761-Fixed Disk 1
does not support
Block Mode
None
Fixed disk drive error.
Run the System
Configuration Utility and
correct.
1771-Primary Disk
Port Address
Assignment Conflict
None
Internal and external
hard drive controllers are
both assigned to the
primary address.
Run the System
Configuration Utility and
correct.
1772-Secondary
Disk Port Address
Assignment Conflict
None
Address Assignment
Conflict. Internal and
external hard drive
controllers are both
assigned to the
secondary address.
Run the System
Configuration Utility and
correct.
1773-Primary Fixed
Disk Port
Assignment Conflict
None
Fixed disk drive error.
Run the System
Configuration Utility and
correct.
1776-Drive Array -
SCSI Port
Termination Error
None
External and internal
SCSI drives are both
configured to Port 1.
Re-configure drives.
1777-Drive Array
Error
None
Cooling fan failure,
internal temperature alert
or open cover.
Inspect for cooling fan
failure or open cover.
1778-Drive Array
resuming Automatic
Data Recovery
process
None
This message appears
whenever a controller
reset or power cycle
occurs while Automatic
Data Recovery is in
progress.
No action necessary.
1779-Drive Array
Controller detects
replacement drives
None
Intermittent drive failure
and/or possible loss of
data.
If this message appears
and drive X has not been
replaced, this indicates
an intermittent drive
failure. This message
also appears once
immediately following
drive replacement
whenever data must be
restored from backup.
Continued