RA8000 and ESA12000 Storage Subsystems
4–14
387404–001
EK–SMCPR–UG. A01
Table 4–4 EMU Fault Code LED Displays (continued)
Display
Fault Code, Cause, Corrective Action
Fault Code 0F
Initial Display
Less than four operational power supplies
remain.
Replace the defective power supplies.
Standby Power Mode Display
Power has been removed from the enclosure.
Comment—The EMU places the system in the
standby power mode for this fault indication. After
replacing the defective power supplies,
momentarily press the alarm control switch to
restore dc power to the enclosure.
The initial display appears when a fault is
detected.
The standby power mode display appears after
the EMU removes dc power from the enclosure.
Fault Code 10
EMU diagnostic program is loaded.
The audible alarm is ON continuously and it
cannot be cleared by pressing the alarm control
switch.
1. Load new microcode. The array controllers
must be RESET to recognize the new
microcode.
2. Replace the EMU with one containing the
proper microcode. The array controllers must
be RESET to recognize the new microcode.