3. Safety regulations
9
Danger
Safety measure required
Compression results in high
temperatures.
The system should be set up such that hazardous mixtures (inflammable
solvent vapours etc. but also dusts and other dangerous or toxic materials)
cannot be drawn in. The same applies to flying sparks.
Never use the machine in environments where the possibility cannot be ruled
out that inflammable or toxic vapours may be taken in.
The installation is to be set up in such a way that it is adequately accessible
and that the necessary cooling is ensured. Never block the admission of air.
Compressor units must never be operated in areas subject to explosion
hazards! (Exception: Special units with the corresponding technical
modifications)
There is strong suction at the air inlet.
The air intake is to be designed in such a way that no loose clothing can be
drawn in.
There is a risk of injury, e.g. from getting
stuck or being drawn in.
The personnel must not have long, loose hair, or wear loose clothing or
jewellery, including rings, due to risk of injury through catching. Personal
protective equipment should be worn if necessary.
Connected compressed air tools may
start up unexpectedly when switching
on.
Before switching on the machine / installation, or starting it up, make sure that
nobody can be injured by the machine / installation as it starts up.
Compressed air may contain
substances that may damage your
health if inhaled.
The compressed air produced by these compressors must not be used as
breathable air, unless it has been processed specially for such an application
in accordance with the “Safety requirements for breathable air.”
When breathing apparatus with cartridges is used, make sure that the correct
cartridge has been inserted and that its service life has not expired.
The safety valves in the system only
guarantee the pressure relief for the
compressor unit.
The pressure devices/systems connected to the compressor must be secured
allowing for the weakest pressurised component (safety valve or similar).
As a rule:
If several compressors are arranged in a system, manually operated valves
have to be installed so that each machine may be shut off individually. For the
purpose of shutting off pressurized systems, you should never rely on the
effectiveness of return valves alone.
All pressure tanks located outside the unit with an approved operating
pressure higher than atmospheric pressure and fitted with two or more
pressure feed lines must be equipped with an additional safety device to
automatically prevent the approved operating pressure from being exceeded
by more than 10%.
Never operate the system at temperatures and/or pressures below or above
the values indicated in the technical data sheet.
Содержание D110H RS
Страница 2: ......
Страница 58: ...11 Annex 56 11 2 Layout plan 11 2 1 Layout plan D110H RS Fig 32 all dimensions in mm...
Страница 59: ...11 Annex 57 Fig 33 all dimensions in mm...
Страница 60: ...11 Annex 58 11 2 2 Layout plan D50H RS D75H RS Fig 34 all dimensions in mm cooling air cooling air...
Страница 61: ...11 Annex 59 Fig 35 all dimensions in mm...
Страница 63: ......