3. Safety regulations
10
3.4
Particular dangers associated with machines
Danger
Safety measure required
Risk of electric shock.
Electrical connections must meet the local regulations. Power units must be
connected to earth and protected from short-circuits by means of fuses.
Insufficient power quality could have
a strong effect on health & safety and
may constitute a risk to life and limb
of the user or third persons.
Always check a correct power supply to the compressor before commissioning.
The voltage supply has to fulfill the requirements of EN60204-1/IEC60204-1 for
such kind of industrial equipment.
Remote-controlled units may start up
unexpectedly.
If a remote control is used, the system must carry a clearly visible sign with the
following note: Attention! This installation is operated by remote control and can
start up without prior warning!
As an additional safety measure, persons, who start remotely controlled systems,
have to take sufficient safety precautions in order to ensure that nobody is
checking the system or working on it. For this, a label with a corresponding
warning notice has to be attached to the remote control equipment.
Noise, even when it is not very loud,
can make us nervous and irritated,
and after a longer period of time our
nervous system can suffer serious
damage.
We recommend a separate machine room in order to keep the noise of the
machine away from the workshop.
Where necessary, wear the personal hearing protection.
In order to consider all noise-relevant parameters and to adequately protect the
health of the operator, the European Regulation 2003/10/EC must be satisfied
completely by the user. In states outside the European Community, the
respective noise protection directives must be taken into consideration.
Shielding and doors must be closed during operation so that the efficiency of the
sound insulating is not reduced.
3.5
Particular dangers associated with water-cooled units
Danger
Safety measure required
If open cooling towers are used in the
cooling water circuit, it is possible for
legionella (Legionella pneumophila)
and other bacteria to grow and
spread.
The growth and spread of bacteria must be prevented by corresponding service
and water treatment methods.
Содержание D110H RS
Страница 2: ......
Страница 58: ...11 Annex 56 11 2 Layout plan 11 2 1 Layout plan D110H RS Fig 32 all dimensions in mm...
Страница 59: ...11 Annex 57 Fig 33 all dimensions in mm...
Страница 60: ...11 Annex 58 11 2 2 Layout plan D50H RS D75H RS Fig 34 all dimensions in mm cooling air cooling air...
Страница 61: ...11 Annex 59 Fig 35 all dimensions in mm...
Страница 63: ......