Guide:
SYSTIMAX
®
iPatch
®
Panel Manager Guide
2–2
An Alternate Configuration
An alternate iPatch System configuration consists of the components listed below.
This system configuration allows the voice and data network administrator to
manage equipment rooms in areas where access to the Ethernet network is not
available or is restricted because of data security considerations.
iPatch System Manager Software running on a PC connected to an Ethernet
network.
a Rack Manager Plus in each building or on each floor that is connected to the
same Ethernet network as the PC.
a Rack Manager Plus
in each equipment room that is connected using the
Network Manager LAN to the one Rack Manager Plus connected to the Ethernet
network.
a Rack Manager Plus
on each rack with iPatch Panels. All of the Rack Manager
Plus units in each equipment room are connected to each other (including the
Rack Manager Plus connected to the Network Manager LAN) using a Rack
Manager LAN.
iPatch Panels on each rack, which are connected to the rack’s Rack Manager
Plus using the panel bus.
In this configuration, the System Manager Software can be used to send scheduled
jobs to the iPatch equipment in each equipment room. The equipment in the
equipment room alerts System Manager to any patching changes and to any
problem conditions in the room.
Communications from the iPatch equipment in each equipment room are routed:
over the Rack Manager LAN for the equipment room to the Rack Manager Plus
connected to the Network Manager LAN
via that Rack Manager Plus to the Network Manager LAN
over the Network Manager LAN for the floor or building to the one Rack
Manager Plus
connected to the Ethernet network
via that Rack Manager Plus to the Ethernet network
over the Ethernet network to the System Manager Software.
A patching job scheduled at System Manager is routed to the iPatch equipment in
the equipment room where the job is to be performed, reversing the path described
above.
A Stand-Alone System Configuration
The simplest iPatch System configuration consists of:
an iPatch Manager on each rack with iPatch Panels. All of the iPatch Manager
units in each equipment room are connected to each other using a Rack
Manager LAN.
iPatch Panels on each rack, which are connected to the rack’s iPatch Manager
using the panel bus.
This “stand-alone” configuration does not require any connections to the Ethernet
network and does not include the System Manager Software. This system provides
tracing information to assist technicians and alerts technicians to problem
conditions in the equipment room. However, this configuration does not provide the
system’s guided patching features, and cannot alert the voice and data network
administrator to problem conditions in the equipment room.