The 

imVision 

System 

Manager 

software  also  alerts  the  administrator 
to  conditions  such  as  unauthorized 
changes to the physical infrastructure, 
or  work  that  was  not  performed  as 
scheduled. 

Please  note  that  the  imVision 
Controller  requires  imVision  System 
Manager  software  version  7.0  or 
higher. 
 

 

 

Settings 

Through the imVision Controller, you  can  change  the  settings  for  a  number  of the 

system’s  administrative 

functions, run

 

equipment tests, reset racks and panels and view rack and controller configuration.

 

Patching Mode 

The imVision System has three settings for  Patching  Mode:  Normal,  Local  and

 

Equipment.  The  patching 

mode at the rack is set to Normal by default. The patching mode can be changed temporarily at the imVision 
controller,  but  the  mode  set  in  System  Manager  software  will  override  a

 

locally  set  mode  during 

synchronization.  When  the  patching  mode  is  set  to something other than Normal, the imVision  Controller 
shows the patching mode on the Idle  screen  below  the  Rack  Name.

 

 

The patching mode is set to Normal when  the Jobs button is pressed.

 

Normal 

All imVision Controllers in this mode monitor connections simultaneously for a given Controller  LAN.

 

Local 

Unless the Jobs button is pressed, each imVision Controller monitors only the activity in its own rack, creating 

“local” patching zone.

 

Equipment 

Unless the Jobs button is pressed, an imVision Controller in Equipment mode will treat each connection as an 
equipment connection, eliminating the need to press and hold the port button for 2 seconds.

 

Patching and Tracing 

Be sure to follow onscreen instructions while performing any activity on iPatch panels. The display will provide 
critical information and feedback throughout your work. 

Performing Guided Patching Jobs 

With the imVision System, the network  administrator  sends  patching  jobs  directly  to  the  rack  via  the  imVision 
System  Manager  software.  On  the  imVision  Controller,  technicians  can  simply  view  the  list  of  jobs  to  be 
performed  and  follow  the  onscreen  instructions  for  adding  or  removing  connections  between  iPatch  panels.  

Содержание SYSTIMAX imVision

Страница 1: ... Instructions 2 The imVision System 3 iPatch Panel 3 imVision Controller 3 Ordering Panels in the imVision System 4 Following Prompts in the imVision System 5 Screen Lock PIN Feature 5 Audible and Visible Feedback 6 imVision System Manager Software 6 Settings 7 Patching Mode 7 Patching and Tracing 7 Performing Guided Patching Jobs 7 Performing Unguided Patching Jobs 8 Tracing a Patch Connection 8 ...

Страница 2: ... product on an unstable cart stand or table The product may fall causing serious damage to the product When installing iPatch equipment not described in this guide follow the instructions provided with that equipment Take care not to compromise the stability of the rack by installation of equipment The touchscreen display is designed to be used without the need for a stylus Never use sharp objects...

Страница 3: ... sensor changes at the iPatch panels By monitoring button presses and sensor changes at the panels the imVision Controller logically infers when patch connections are added or deleted and updates the database accordingly In most configurations multiple imVision Controller units are grouped and connected into patching zones Each patching zone requires a LAN connection in order to communicate with t...

Страница 4: ... the rack and so on Press each button to hear a tone confirming its inclusion in the order until all the panels in the rack are numbered At that point the tone will change and the imVision System will enter the Ready state with the Home screen appearing on the interface If the rack includes a high density fiber shelf or shelves you must also order the modules by pressing a button on each module of...

Страница 5: ...y Screen Lock PIN Feature When enabled the Screen Lock PIN feature locks an imVision Controller display until a PIN is entered on the display number keypad Touch the lock icon on the bottom right corner of display to show a keypad then enter PIN to unlock the display screen Enable the screen lock PIN feature by entering the Controller Settings menu on the Home screen Choose Screen Lock Settings ch...

Страница 6: ...ort beep Pressed controller key Inserted or removed a patch cord at an iPatch Panel Completion tone 3 short tones low medium high Added or removed patch connection at an iPatch Panel Indicated the position of a row of iPatch Panel ports Saved a network setting Confirmation tone 2 short tones Programmed the order of the panels and modules in the rack Attention tone 1 long low tone Technician is req...

Страница 7: ...ormal the imVision Controller shows the patching mode on the Idle screen below the Rack Name The patching mode is set to Normal when the Jobs button is pressed Normal All imVision Controllers in this mode monitor connections simultaneously for a given Controller LAN Local Unless the Jobs button is pressed each imVision Controller monitors only the activity in its own rack creating a local patching...

Страница 8: ...m the iPatch Panel unplug the patch cord from the equipment Then disconnect the patch cord from the panel Press and hold the button above the newly vacated port on the iPatch Panel for 2 seconds This will confirm that the unguided equipment patch removal has been completed Tracing a Patch Connection When you connect a patch cord to an iPatch Panel the system records the connection in a database To...

Страница 9: ...ced port Step 3 Confirm the correct connection for each port After using the Change button the imVision Controller will automatically step through each port that was involved in the changed connection For each port a Confirm screen will appear to provide guidance for confirming the connection information Follow the on screen instructions to create a new connection relationship between ports or wit...

Страница 10: ...t the patch connection you want to confirm Then either Press and hold the port button in the panel directly above the port where the other end of the cord is inserted and confirm on the display that the connection is complete or If the other end of the patch cord is hanging free plug in the cord and answer Yes to the question Insert one end of the patch cord and press and hold the button on the pa...

Страница 11: ...ther the B or A strand is the far end of the patch being confirmed When the correct connection is displayed press Yes Complete the connection to equipment Press and hold the iPatch panel port s button for 2 seconds or press the Equipment button on the imVision Controller display Remove the connection Remove both ends of the patch cord Connecting Controllers in a Zone A zone is a group of racks and...

Страница 12: ...ed if the port is used to connect from the imVision Controller to another controller in the zone The Controller mode is selected when the button next to a port is in the pushed out position When pushed out the button is flush with the controller housing The example above shows the patch cord connections and button positions required to configure a zone containing three imVision Controllers ...

Страница 13: ...rder ofiPatch equipment in the rack You attempt to trace a patch connection and the LEDs do not turn on where you expect a Patch cord is not connected where it is supposed to be b Wrong connection has been recorded in the database a Manually trace the patch connection to determine the other end of the connection Remove the patch cord and reconnect the patch cord to the proper ports b Use the Trace...

Страница 14: ...roperly for the current patching b imVision Controller is not connected to the adjacent imVision controller c imVision Controller has failed d imVision Controller is not responding e Panel or module is not communicating with the imVisionController f Patch cord connecting an imVision Controller to an adjacent controller failed a At each imVision controller press Home to view the controller configur...

Страница 15: ... a The Controller in question has lost power b The Controller in question is improperly connected to the other controllers in the patching zone c The Controller in question does not have its IN and OUT port switches configured correctly d The Controller has been removed from the patching zone in question e The Controller in question has failed a Make sure the Controller is properly connected to it...

Отзывы: