nstallatIon
A communicating furnace matched with a communicating outdoor AC condensing
unit
A communicating furnace matched with a communicating outdoor heat pump unit
A communicating furnace matched with a non-communicating, single stage AC
condensing unit
System configurations other than those noted above will not function or may function
properly at greatly reduced performance.
B
attery
l
oCation
2 “AA” alkaline batteries are included in the
control with a battery tag to prevent power
drainage. The battery tag must be removed
to engage the batteries. The batteries are
required to maintain time during a power
outage. They are also required for armchair
programming.
If
“LOW BATTERY”
is displayed in the
scrolling area, the batteries are low and
should be replaced with fresh batteries. For
best results, use premium brand alkaline
batteries.
To replace batteries, set control system touch key to OFF, remove control from wall by
grasping the top and bottom of the control and pulling straight away from the wall. The
base will remain on the wall. Install the batteries in the rear along the top of the control.
Reposition the control over the base plate and gently snap into place.
2 "AA" Batteries
h
eat
S
et
-
uP
(h
eat
P
umP
o
nly
)
Sub-menu Item
User Modifiable
Options
Comments
Heat Airflow Trim
(HT TRM)
-10% to +10% in 2%
Increments
Selects the airflow trim amount;
applies to heat pump only.
Heat ON Delay
(HT ON)
5, 10, or 15 seconds
(5-min. default)
Selects the indoor blower on delay;
applies to heat pump only.
Heat OFF Delay
(HT OFF)
30, 50, 70, or 90 seconds
(30-min. default)
Selects the indoor blower off delay;
applies to heat pump only.
Defrost Interval
(DEFROST)
30, 60, 90, or 120 min-
utes (30-min. default)
Selects the time interval between
defrost; applies to heat pump only.
Compressor Delay
(CMP DLY)
0, 5, 15, or 30 seconds
(5-min. default)
Selects the compressor off time after
a reversing valve shift; applies to heat
pump only.
Status
Sub-menu Item
Indication (for Display Only; not User Modifiable)
Mode (MODE)
Displays the current air handler operating mode
CFM (CFM)
Displays the airflow for the current operating mode