Alternate indoor unit to outdoor unit wiring: In some installations, only two wires 

may be available for low voltage control wiring at the outdoor unit. If this is the case, 

use  the  existing  low  voltage  control  wires  and  connect  the  1,  and  2  terminals  as 

shown in the figure below. Follow instructions below to wire the system.

°  Install  the  supplied  40  VA  transformer  in  the  outdoor  unit  using  the  screws 

provided. Align the holes in the transformer mounting bracket with the holes in 

the sheet metal mounting panel and secure with screws.

°  Connect one terminated end of the black 22” wire jumper to the 240VAC terminal 

on  the  transformer  (or  208VAC  terminal  if  208VAC  system).  Connect  the  other 

terminated end of the wire jumper to L1 on the outdoor unit’s control.

°  Connect the red 22” wire jumper to the 240VAC COM terminal on the transformer. 

Connect the other end of the wire jumper to L2 on the outdoor unit’s control.

°  Connect the terminated end of the red 14” wire jumper to the 24VAC terminal on 

the transformer. Connect the other end to the “R” terminal on the included plug 

connector.

°  Connect  the  terminated  end  of  the  blue  14”  wire  jumper  to  the  24VAC  COM 

terminal  on  the  transformer.  Connect  the  other  end  to  the “C”  terminal  on  the 

included plug connector.

h

eat

 P

umP

/a

ir

 C

onDitioner

 u

Ser

 m

enuS

C

onfiguration

Sub-menu Item

Indication (for Display Only; not User Modifiable)

Number of AC Stages 

(CL STG)

Displays the number of air conditioning stages; applies to AC 

and HP.

Number of HP Stages 

(HT STG)

Displays the number of heat pump stages; applies to HP only.

AC Tonnage (TONS)

Displays the air conditioning tonnage; applies to AC and HP.

D

iagnoStiCS

Sub-menu Item

Indication/User 

Modifiable Options

Comments

Fault 1 (FAULT #1)

Most recent AC/HP fault

For display only

Fault 2 (FAULT #2)

Next most recent AC/HP fault For display only

Fault 3 (FAULT #3)

Next most recent AC/HP fault For display only

Fault 4 (FAULT #4)

Next most recent AC/HP fault For display only

Fault 5 (FAULT #5)

Next most recent AC/HP fault For display only

Fault 6 (FAULT #6)

Least recent AC/HP fault

For display only

Clear Fault History 

(CLEAR)

NO or YES

Selecting “YES” clears the fault 

history

i

DentifiCation

Sub-menu Item

Indication (for Display Only; not User Modifiable)

Model Number  

(MOD NUM)

Displays the air conditioner or heat pump model number

Serial Number 

(SER NUM)

Displays the air conditioner or heat pump serial number 

(Optional)

Software (SOFTWARE) Displays application software revision

Touchscreen

Thermostat

Indoor

Board Terminal

Connections

Outdoor

Board Terminal 

Connections

R

C

1

2

R

C

1

2

1

2

R

C

24VAC (Hot)

24VAC

230V

24VAC

(Common)

Data 1

Data 2

Outdoor 40VA

Transformer

NOTE:

 Consecutively repeated faults are shown a maximum of 3 times.

°  Dual Fuel Systems:  It is highly recommended that the supplied 40VA transformer 

be used in the outdoor unit. See Alternate indoor unit to outdoor unit wiring 

for transformer wiring instructions.

°  To  maintain  the  UL  rating  on  all  AC  and  heat  pump  models  the  installing 

contractor is required to use the low voltage wiring provided inside the control 

panel when converting to the communicating control system.

Содержание CTK01

Страница 1: ...INSTALLATION POWER UP SETUP USAGE GUIDE ADVANCED MENUS Installation and Start Up Instructions An Exclusive Touchscreen Control Featuring Serial Communication Model CTK01...

Страница 2: ...el applications dehumidification filter maintenance reminders outdoor temperature display and advanced menus The various options and display areas are described below FAILURE TO READ AND FOLLOW ALL IN...

Страница 3: ...r Up 9 Power Up 9 Thermostat Messages 9 Auto Configuration 9 Check System Operation 10 Thermostat Set up 11 Set Current Time and Day 11 Choose the System Setting 12 Energy Saving Factory Program 12 Th...

Страница 4: ...s communicating control kit contains the following components 1 Communicating touchscreen control with sub base 1 230 VAC to 24 VAC 40 VA transformer B1141643 2 Tyco 284041 4 4 position plug color cod...

Страница 5: ...ry tag to prevent power drainage The battery tag must be removed to engage the batteries The batteries are required to maintain time during a power outage They are also required for armchair programmi...

Страница 6: ...system requires four wire connections 24VAC Hot R 24VAC Common C Data 1 1 and Data 2 2 The R and C connections provide a 24VAC power supply that can be shared between the indoor and outdoor units and...

Страница 7: ...r to the 240VAC COM terminal on the transformer Connect the other end of the wire jumper to L2 on the outdoor unit s control Connect the terminated end of the red 14 wire jumper to the 24VAC terminal...

Страница 8: ...stat Pull the thermostat body off the thermostat base Forcing or prying on the thermostat will cause damage to the unit Place base at installation location and mark mounting hole locations on wall usi...

Страница 9: ...hat the equipment has been found with the message equipment FOUND Auto Configuration The system will auto configure itself once all system components have been identified The result is that the system...

Страница 10: ...ng Heating System Press Run Schedule Press to adjust thermostat setting above room temperature The heating system should begin to operate Press to adjust thermostat setting below room temperature The...

Страница 11: ...isplay Touch either the or key until you reach the correct hour and AM or PM designation Then touch Set Time again to display min utes only in clock display Touch and hold either the or keys until you...

Страница 12: ...system Em Emergency setting available only when the thermostat detects a heat pump in the system Auto Auto Changeover is used where both heating and cooling may be required during the same day Auto al...

Страница 13: ...cation setting Default is OFF It can be set in the range of 40 to 94 Above 94 is the OFF setting Ideally the indoor humidity should be set in the range of 40 to 60 When On Demand Dehumidification is s...

Страница 14: ...nged to 0 Days to indicate no programs will be run When set for 7 Days the thermostat will follow the factory program or the program that you entered Select Energy Management Recovery Scrolling Messag...

Страница 15: ...ht will turn on momentarily Select temperature offset Scrolling message will show TEMPERATURE ADJUSTMENT Default is 0 with current temperature Adjustment can be made from 5 Lo to 5 HI to change the di...

Страница 16: ...air filter maintenance reminder Scrolling message will show AIR FILTER MAINTENANCE Default is OFF It can be changed to a setting from 25 to 1975 hours in increments of 25 hours to select the amount of...

Страница 17: ...may be required on the same day Auto allows the thermostat to automatically switch between heating and cooling operation Auxiliary Heating When the thermostat is configured for Heat Pump mode and an...

Страница 18: ...the screen Touch the Hold key to maintain the new set point temperature Hold At will display to the left of the temperature set point To cancel the permanent hold setting at any time and return to th...

Страница 19: ...period The display will show FAN On Prog Check System Status If the Home Screen Display indicates Call for Service and Check Equipment Name inthescrollingmessagearea there is a fault in the system Whe...

Страница 20: ...Installer Config key again for approximately 3 seconds to enter the Advanced Installer Configuration menu 1 2 Fault Status The display will change to the Fault Screen indicating any faults that may b...

Страница 21: ...to enter that equipment sub menu listing The scrolling message area will show WORKING to indicate that the thermostat is retrieving data Then the first equipment sub menu name appears in the scrolling...

Страница 22: ...ange is accepted If the change does not get accepted the display will show FAIL and then change back to the Fault Screen Some of the parameters being displayed on a sub menu are long and switch betwee...

Страница 23: ...eparticular piece of equipment It also provides a means to clear the fault history Identification This sub menu item provides access to the model number and serial number optional for the particular p...

Страница 24: ...led Temperature HP BAL PNT OFF or 0 to 50 F in 5 F increments Available only for air handler heat pump systems Disables heat pump below the selected temperature Balance Point Temperature df BAL PNT OF...

Страница 25: ...horse power Diagnostics Sub menu Item Indication User Modifiable Options Comments Fault 1 FAULT 1 Most recent furnace fault For display only Fault 2 FAULT 2 Next most recent furnace fault For display...

Страница 26: ...number Optional Software SOFTWARE Displays application software revision Set up Sub menu Item User Modifiable Options Comments Heat Airflow Trim HT TRM 10 to 10 in 2 Incre ments Trims the heating airf...

Страница 27: ...tage AC unit Cool Airflow Profile CL PRFL A B C or D Selects the airflow profile for the non communicating 1 stage AC unit Cool ON Delay CL ON 5 10 20 or 30 seconds Selects the indoor blower on delay...

Страница 28: ...t most recent air handler fault For display only Fault 5 FAULT 5 Next most recent air handler fault For display only Fault 6 FAULT 6 Least recent air handler fault For display only Clear Fault History...

Страница 29: ...odifiable Options Comments Heat Airflow Trim HT TRM 10 to 10 in 2 Incre ments Trims the electric heating airflow by the selected amount Status Sub menu Item Indication for Display Only not User Modifi...

Страница 30: ...fault For display only Fault 2 FAULT 2 Next most recent AC HP fault For display only Fault 3 FAULT 3 Next most recent AC HP fault For display only Fault 4 FAULT 4 Next most recent AC HP fault For dis...

Страница 31: ...em User Modifiable Options Comments applies to AC and HP models Cool Airflow Trim CL TRM 10 to 10 in 2 Increments Selects the airflow trim amount applies to air conditioner only Cool Airflow Profile C...

Страница 32: ...Heat OFF Delay HT OFF 30 50 70 or 90 seconds 30 min default Selects the indoor blower off delay applies to heat pump only Defrost Interval DEFROST 30 60 90 or 120 min utes 30 min default Selects the...

Страница 33: ...INSTALLATION POWER UP SETUP USAGE GUIDE ADVANCED MENUS 33 NOTES...

Страница 34: ...means is also the installing contractor for the unit The warranty period begins on the date of the original installation Where the product is installed in a newly constructed home the date of the ins...

Страница 35: ...as described in the installation and operating manual 6 Replacement parts not supplied or designated by Goodman 7 Damage or repairs required as a result of any improper use maintenance operation or se...

Страница 36: ...nication Our continuing commitment to quality products may mean a change in specifications without notice 2009 Goodman Manufacturing Company L P Houston TX For complete information on Goodman warranti...

Отзывы: