This  feature  will  override  the  program  temperature  setting  until  the  next  program 
period begins. Touch   or 

 keys to adjust the temperature. The display will indicate 

Temporary Hold At”

 to the left of the set-point temperature. To cancel the temporary 

setting before the next period begins, touch 

Run Schedule

 to return to the program.

Example: If you turn up the heat during the Morning program, it will remain at the new 

temperature until the time for the next program period (Day).

P

ermanent

 t

emPerature

 h

olD

The  Permanent  Temperature  Hold  feature  bypasses  the  program  and  allows  you  to 

adjust  the  temperature  manually  as  needed.  The  temperature  you  set  in  HOLD  will 

be  maintained  indefinitely.  Touch 

Run  Schedule

  to  cancel  HOLD  and  resume  the 

programmed schedule.
Touch   or 

 keys to adjust the temperature. The 

Hold

 key will appear on the screen. 

Touch the 

Hold

 key to maintain the new set-point temperature. ”

Hold At”

 will display to 

the left of the temperature set-point. To cancel the permanent hold setting at any time 

and return to the program, touch 

Run Schedule

.

Example: If you turn up the heat during the morning program and touch the 

Hold

 key, 

it will remain at the new temperature until you touch 

Run Schedule

 or you manually 

adjust to another temperature.

n

on

-P

rogrammaBle

 m

oDe

If  Program  days  per  week  is  set  for  0  Days  (Non-programmable)  in  the  Thermostat 

Options Configuration Menu, the thermostat will not follow any program periods. Touch 
the 

SYSTEM

  key  to  select 

Heat

  or 

Cool

  and  use  the 

  or 

  buttons  to  adjust  the 

temperature to your desired setting. After selecting your desired settings you can also 

touch the 

SYSTEM

 key to select 

AUTO

 to allow the thermostat to automatically change 

between Heat and Cool. If the 

SYSTEM

 key is touched to select 

Auto

 the thermostat will 

change to Heat or Cool, whichever ran last. If it switches to heat but you want cool, or it 
changes to cool but you want heat, touch both   or 

 keys simultaneously to change 

to the other mode.

C

hooSe

 

the

 fan S

etting

 (a

uto

 

or

 o

n

FAN Auto

 is the most commonly selected setting and runs the fan automatically when 

the heating or cooling system is on during a program period.

Fan  On

  selection  runs  the  fan  continuously  for  increased  air  circulation  or  to  allow 

additional air cleaning. When 

FAN

 is selected 

On

, it will run at the speed selected in the 

Thermostat Options Configuration Menu.

Fan Prog

 - When a period that has 

FAN Prog

 in the program begins, the fan will turn on 

and stay on during the complete period. The display will show 

FAN On Prog.

C

heCK

 S

yStem

 S

tatuS

If the Home Screen Display indicates “

Call 

for  Service

”  and  “

Check  <Equipment 

Name>

” in the scrolling message area, there 

is a fault in the system. When this message 

is  displayed,  contact  your  heating  and 

cooling service contractor or the installing 

contractor for service.

m

aintenanCe

 r

eminDer

 m

eSSage

A  reminder  will  display  in  the  scrolling 

message area when it is time for accessory 

maintenance if selected in the Thermostat 

Options  Configuration  Menu.  When  a 

reminder  appears,  it  can  be  cleared  by 

touching the 

Clean Display

 key. This will 

also  reset  the  timer  to  begin  a  new  time 

period for the reminder.

Air Filter Maintenance

 - When the system 

has run for the selected length of time, the 

scrolling message area will show “

CHANGE 

FILTER”

.

Содержание CTK01

Страница 1: ...INSTALLATION POWER UP SETUP USAGE GUIDE ADVANCED MENUS Installation and Start Up Instructions An Exclusive Touchscreen Control Featuring Serial Communication Model CTK01...

Страница 2: ...el applications dehumidification filter maintenance reminders outdoor temperature display and advanced menus The various options and display areas are described below FAILURE TO READ AND FOLLOW ALL IN...

Страница 3: ...r Up 9 Power Up 9 Thermostat Messages 9 Auto Configuration 9 Check System Operation 10 Thermostat Set up 11 Set Current Time and Day 11 Choose the System Setting 12 Energy Saving Factory Program 12 Th...

Страница 4: ...s communicating control kit contains the following components 1 Communicating touchscreen control with sub base 1 230 VAC to 24 VAC 40 VA transformer B1141643 2 Tyco 284041 4 4 position plug color cod...

Страница 5: ...ry tag to prevent power drainage The battery tag must be removed to engage the batteries The batteries are required to maintain time during a power outage They are also required for armchair programmi...

Страница 6: ...system requires four wire connections 24VAC Hot R 24VAC Common C Data 1 1 and Data 2 2 The R and C connections provide a 24VAC power supply that can be shared between the indoor and outdoor units and...

Страница 7: ...r to the 240VAC COM terminal on the transformer Connect the other end of the wire jumper to L2 on the outdoor unit s control Connect the terminated end of the red 14 wire jumper to the 24VAC terminal...

Страница 8: ...stat Pull the thermostat body off the thermostat base Forcing or prying on the thermostat will cause damage to the unit Place base at installation location and mark mounting hole locations on wall usi...

Страница 9: ...hat the equipment has been found with the message equipment FOUND Auto Configuration The system will auto configure itself once all system components have been identified The result is that the system...

Страница 10: ...ng Heating System Press Run Schedule Press to adjust thermostat setting above room temperature The heating system should begin to operate Press to adjust thermostat setting below room temperature The...

Страница 11: ...isplay Touch either the or key until you reach the correct hour and AM or PM designation Then touch Set Time again to display min utes only in clock display Touch and hold either the or keys until you...

Страница 12: ...system Em Emergency setting available only when the thermostat detects a heat pump in the system Auto Auto Changeover is used where both heating and cooling may be required during the same day Auto al...

Страница 13: ...cation setting Default is OFF It can be set in the range of 40 to 94 Above 94 is the OFF setting Ideally the indoor humidity should be set in the range of 40 to 60 When On Demand Dehumidification is s...

Страница 14: ...nged to 0 Days to indicate no programs will be run When set for 7 Days the thermostat will follow the factory program or the program that you entered Select Energy Management Recovery Scrolling Messag...

Страница 15: ...ht will turn on momentarily Select temperature offset Scrolling message will show TEMPERATURE ADJUSTMENT Default is 0 with current temperature Adjustment can be made from 5 Lo to 5 HI to change the di...

Страница 16: ...air filter maintenance reminder Scrolling message will show AIR FILTER MAINTENANCE Default is OFF It can be changed to a setting from 25 to 1975 hours in increments of 25 hours to select the amount of...

Страница 17: ...may be required on the same day Auto allows the thermostat to automatically switch between heating and cooling operation Auxiliary Heating When the thermostat is configured for Heat Pump mode and an...

Страница 18: ...the screen Touch the Hold key to maintain the new set point temperature Hold At will display to the left of the temperature set point To cancel the permanent hold setting at any time and return to th...

Страница 19: ...period The display will show FAN On Prog Check System Status If the Home Screen Display indicates Call for Service and Check Equipment Name inthescrollingmessagearea there is a fault in the system Whe...

Страница 20: ...Installer Config key again for approximately 3 seconds to enter the Advanced Installer Configuration menu 1 2 Fault Status The display will change to the Fault Screen indicating any faults that may b...

Страница 21: ...to enter that equipment sub menu listing The scrolling message area will show WORKING to indicate that the thermostat is retrieving data Then the first equipment sub menu name appears in the scrolling...

Страница 22: ...ange is accepted If the change does not get accepted the display will show FAIL and then change back to the Fault Screen Some of the parameters being displayed on a sub menu are long and switch betwee...

Страница 23: ...eparticular piece of equipment It also provides a means to clear the fault history Identification This sub menu item provides access to the model number and serial number optional for the particular p...

Страница 24: ...led Temperature HP BAL PNT OFF or 0 to 50 F in 5 F increments Available only for air handler heat pump systems Disables heat pump below the selected temperature Balance Point Temperature df BAL PNT OF...

Страница 25: ...horse power Diagnostics Sub menu Item Indication User Modifiable Options Comments Fault 1 FAULT 1 Most recent furnace fault For display only Fault 2 FAULT 2 Next most recent furnace fault For display...

Страница 26: ...number Optional Software SOFTWARE Displays application software revision Set up Sub menu Item User Modifiable Options Comments Heat Airflow Trim HT TRM 10 to 10 in 2 Incre ments Trims the heating airf...

Страница 27: ...tage AC unit Cool Airflow Profile CL PRFL A B C or D Selects the airflow profile for the non communicating 1 stage AC unit Cool ON Delay CL ON 5 10 20 or 30 seconds Selects the indoor blower on delay...

Страница 28: ...t most recent air handler fault For display only Fault 5 FAULT 5 Next most recent air handler fault For display only Fault 6 FAULT 6 Least recent air handler fault For display only Clear Fault History...

Страница 29: ...odifiable Options Comments Heat Airflow Trim HT TRM 10 to 10 in 2 Incre ments Trims the electric heating airflow by the selected amount Status Sub menu Item Indication for Display Only not User Modifi...

Страница 30: ...fault For display only Fault 2 FAULT 2 Next most recent AC HP fault For display only Fault 3 FAULT 3 Next most recent AC HP fault For display only Fault 4 FAULT 4 Next most recent AC HP fault For dis...

Страница 31: ...em User Modifiable Options Comments applies to AC and HP models Cool Airflow Trim CL TRM 10 to 10 in 2 Increments Selects the airflow trim amount applies to air conditioner only Cool Airflow Profile C...

Страница 32: ...Heat OFF Delay HT OFF 30 50 70 or 90 seconds 30 min default Selects the indoor blower off delay applies to heat pump only Defrost Interval DEFROST 30 60 90 or 120 min utes 30 min default Selects the...

Страница 33: ...INSTALLATION POWER UP SETUP USAGE GUIDE ADVANCED MENUS 33 NOTES...

Страница 34: ...means is also the installing contractor for the unit The warranty period begins on the date of the original installation Where the product is installed in a newly constructed home the date of the ins...

Страница 35: ...as described in the installation and operating manual 6 Replacement parts not supplied or designated by Goodman 7 Damage or repairs required as a result of any improper use maintenance operation or se...

Страница 36: ...nication Our continuing commitment to quality products may mean a change in specifications without notice 2009 Goodman Manufacturing Company L P Houston TX For complete information on Goodman warranti...

Отзывы: