Comfortflame.US.com
900563-00NC
3
SAFETY
Continued
You must operate this fireplace with the provided
fireplace screen, hood if provided, in place. Make
sure these parts are in place and screens are closed
before running firebox. The supplied hood may not
be replaced with a hood which may be provided with
a log heater.
Keep the fireplace area clear and free from combus-
tible materials, gasoline and other flammable vapors
and liquids.
THE FIREBOX CANOPY (HOOD) MUST NOT BE MODI-
FIED OR REPLACED WITH A CANOPY (HOOD) THAT
MAY BE PROVIDED WITH THE UNVENTED DECORATIVE
ROOM HEATER.
1. Do not use this firebox as a wood-burning fireplace. Use only
decorative unvented room heaters (log sets).
2. Do not add extra logs or ornaments such as pine cones,
vermiculite or rock wool. Using these added items can cause
sooting.
3. Use only the provided hood or appropriate hood accessory. See
Accessories on page 18.
4. Vent-free gas log heaters installed in these fireboxes require
fresh air ventilation to run properly. See Air for Combustion and
Ventilation, page 8.
5. Do not run firebox
• where flammable liquids or vapors are used or stored
• under dusty conditions
6. Do not use this firebox to cook food or burn paper or other objects.
7. Turn firebox off and let cool before servicing. Only a qualified
service person should service and repair firebox.
8. Operating firebox above elevations of 4,500 feet could cause pilot
outage.
9. Do not use the firebox if it has been under water due to the shock
hazard that could result with the blower accessary (if installed) in
place.
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence
of local codes, use the latest edition of The National Fuel Gas Code,
ANSI Z223.1/NFPA 54*. Firebox must be electrically grounded in
accordance with the National Electrical Code, ANSI/NFPA70 (latest
edition).
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street, 4th floor
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02169-7471
State of Massachusetts:
The installation must be made by a licensed
plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental
room heaters shall provide to each purchaser a copy of 527 CMR
30 upon sale of the unit.
Vent-free gas products are prohibited for bedroom and bathroom
installation in the Commonwealth of Massachusetts.
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
These appliances are approved for installation in the US state of
Massachusetts if the following additional requirements are met:
• Un-vented Room Heaters shall be installed in accordance with
527 CMR 30.
• Installation and repair must be done by a plumber or gas fitter
licensed in the Commonwealth of Massachusetts.
• The flexible gas line connector used shall not exceed 36 inches
(92 centimeters) in length.
• The individual manual shut-off must be a T-handle type valve.
• Unvented appliances may NOT be installed in bedrooms or
bathrooms.
• A working smoke detector must be installed in the area where
vent-free appliances are installed.
Seller of unvented propane or natural gas-fired supplemental room
heaters shall provide to each purchaser a copy of 527 CMR 30 upon
sale of the unit.