Comfortflame.US.com
900563-00NC
14
Figure 13 - Accessing Blower Compartment (Controls Not Shown for
Clarity)
Front
Refractory
Panel
Bottom
Louver
Control
Access
Cover
Control
Access
Option for
Radiant
models
only
Figure 14 - Accessing Duplex Electrical Outlet Installed in
Bottom Right Side of Firebox
Accessing Blower Compartment
Decide which way you intend to gain access into the bottom rear of
the firebox to install the blower accessory (Louvered models only).
Radiant Models:
Accessibility to the bottom, can only be gained
through the access panel underneath the bottom front refractory brick
liner (see Figure 13). Lift the bottom front refractory brick liner up and
out of the firebox floor, exposing the rectangular shaped access cover
(see Figure 13). The sides and back refractory brick liner pieces do
not have to be removed. Lift access panel out by using finger holes.
Blower accessory BK can now be installed
Louvered Models:
Accessibility to the bottom, can be gained through
the access panel underneath the bottom front refractory brick liner
and thru the bottom louver opening. Lift the bottom front refractory
brick liner up and out of the firebox floor, exposing the rectangular
shaped access cover (see Figure 13). The sides and back refractory
brick liner pieces do not have to be removed. Lift access panel cover
out by using finger holes. Blower accessory BK can now be installed.
If accessing thru the louver opening, remove bottom louver panel by
simultaneously pulling both top end spring latches towards center of
appliance until they are disengaged from locating holes (see Figure
13a). Repeat for bottom spring latches and pull louver outward. To
install or replace items removed, simply reverse procedures above.
WARNING: If there is a duplex electrical outlet
installed in the right side of the bottom of the fireplace
base area (see Figure 14), be sure that the electrical
power to the outlet is turned off before proceeding
with blower installation. Failure to do this may result
in serious injury.
Model BK Installation
1. Be certain that all wire terminals are securely attached to terminals
on blower motor and that the screw retaining the green ground
wire is tight (see Figure 15).
2. Place blower against lower rear wall of firebox outer wrapper with
exhaust port directed upward. Depending on your model, you may
have to carefully route the blower assembly past controls and
brackets and position blower inside back opening. The blower will
be held in position against the back wall by magnets incorporated
onto blower housing (see Figures 15 and 16).
INSTALLATION
Continued
Figure 16 - Blower Model BK (Side View)
Figure 15 - Blower Model BK
Magnetic Strips
Exhaust
Port
Screw
Green
Ground
Wire
Spade
Terminals
Side View
Firebox Bottom
Air Flow
Direction
Blower
Installed After
Lower Panel
Removed
Blower
Location
Magnets
Figure 13a - Removing Louver Panel
Louver
Panel
Spring
Latch
Duplex
Electrical
Outlet