The range hood is designed to remove smoke and cook-

ing vapors from the cooktop area. For best results, start 

the hood before cooking and allow it to operate several 

minutes after the cooking is complete to clear all smoke 

from the kitchen.

Range Hood Controls

Operating the Light

Operating the Fan

Cleaning

WARNING

To Reduce The Risk Of Fire Or Electrical shock 

disconnect from power supply before cleaning.

 

IMPORTANT

Clean the hood and grease filters frequently 

according to the following instructions. Replace 

grease filter before operating hood.

 

IMPORTANT

Exterior Surfaces

Do not use soap-fi

lled scouring pads, abrasive cleaners, 

Cooktop Polishing Creme, steel wool, gritty washcloths 

or paper towels.

To avoid damage to the stainless steel, do not use 

cleaners that contain chlorine.

Cleaning Method:

RANGE HOOD USE INSTRUCTIONS

B

A

C

A. LED lights

B. Grease filter

C. Control knobs

The hood controls are located at the bottom 

front section of the unit. 

 

Push Motor Switch

一 :

M

otor Low 

Position

二:

Motor High Position

o

:Motor Off

Push lamp Switch 

Stainless Steel cleaners or any other types of cleaners 

containing  any  abrasive, c hlorides, c hlorines or ammonia. 
It  is  recommended  to use mild  dish  soap  and water or a 
50/50 solution of water and vinegar. 

Clean  the  stainless  with  warm  soapy water  using  a 

clean sponge or cloth. Rinse with clean  water and dry 
with a soft clean cloth. DO NOT  USE any  cleaners like

Lamp Switch

Motor Switch

6

USE INSTRUCTIONS

Содержание CVU30W2AST

Страница 1: ...Free 3 months extension of the original limited warranty period Simply text a picture of your proof of purchase to 1 844 224 1614 The warranty extension is for the three months immediately following t...

Страница 2: ...d by the manufacturer If you have questions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power fro...

Страница 3: ...of failure to observe the instructions given here for installation maintenance and suitable use of the product The manufacturer further declines all respon sibility for injury due to negligence and t...

Страница 4: ...ection of copper wire using special conectors and or tools designed and UL listed for joining copper to aluminum Follow the electrical connector manufacturer s recom mended procedure Aluminum copper c...

Страница 5: ...conform to the Manufactured Home Construction Safety Standards Title 24 CFR Part 328 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard...

Страница 6: ...ve cleaners Cooktop Polishing Creme steel wool gritty washcloths or paper towels To avoid damage to the stainless steel do not use cleaners that contain chlorine Cleaning Method RANGE HOOD USE INSTRUC...

Страница 7: ...ING d r a z x a H k c o h S l a c i r t c e l E Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock NOTE The grease...

Страница 8: ...close as possible to where the vent system enters the heated portion of the house Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater than...

Страница 9: ...les locations Install horizontal s t a s d u t s l l a w o w t n e e w t e b 2 X 4 t s a e l t a t r o p p u the rear mounting screw holes location The horizontal support must be flush with the room s...

Страница 10: ...abinet cutouts From wall not cabinet frame Centerline 5 The actual size of the product is below and the user is installed according to the actual demand 3 The actual size of the product is below and t...

Страница 11: ...ne on the underside of cabinet Use saber or keyhole saw to cut a rectangular opening for vent Repeat steps 1 3 for the underside of the top of the cabinet 1 2 3 4 5 The actual size of the product is b...

Страница 12: ...able according to the National Electric Code or CSA standards and local codes and ordinances 1 For roof installations remove the top rectangular For wall installations remove the NOTE Remove the screw...

Страница 13: ...all so that the screws are in the neck of the slots Tighten the mounting screws making sure the screws are in the narrow neck of slots Connect ventwork to hood Seal joints with vent clamps or duct tap...

Страница 14: ...sure the wires on light switch are connected properly The hood is not venting out properly 1 The hood might be hanging to high from the cook top 2 The wind from the opened windows or opened doors in...

Страница 15: ...rice Every implied warranty including any statutory warranty or condition of merchantability RU WQHVV IRU SDUWLFXODU SXUSRVH LV GLVFODLPHG H FHSW WR WKH H WHQW SURKLELWHG E ODZ LQ ZKLFK FDVH VXFK ZDUU...

Страница 16: ......

Отзывы: