Mark a line distance (A) from the right of the
centerline on the underside of the wall. Mark the point
on this line that is fr
om the underside of
the cabinet. Drill a 1.25” (32 mm) diameter hole (B)
through the rear wall at this point.
1.
A
Centerline
B
A
A Centerline
B
Mark a line distance (A) from the right of the
centerl ine on the underside of the cabinet. Mark the
point on this line that is from back wall. Drill a
1.25” (32 mm) diameter hole (B) through the
cabinet at this point.
2.
Determine Wiring Hole Location
Determine and clearly mark a vertical centerline on
the wall and cabinet bottom.
1.
A
A Centerline
Range Hood Location Preparation
Roof Venting
cutout on the underside of cabinet top and bottom:
Mark lines from the back wall on the centerline of
the underside of cabinet.
Mark lines to the right and left of the centerline on the
underside of cabinet.
Use saber or keyhole saw to cut a rectangular opening
for vent.
Repeat steps 1-3 for the underside of the top of the
cabinet.
1.
.
.
4
.
Cabinet
cutouts
*
From wall, not cabinet
frame
Centerline
5
.
The actual size of the product is below, and the user
is installed according to the actual demand
3
.
The actual size of the product is below, and the user
is installed according to the actual demand
2
.
The actual size of the product is below, and the user
is installed according to the actual demand
Wall Venting
18
0m
m
2
0m
m
18
0m
m
2
0m
m
Wall Venting
To make a 4 ” x 10.5” (108 mm x 267 mm) rectangle in
the wall:
Mark lines from the back wall on the centerline of
the underside of cabinet.
Mark lines to the right and left of the centerline on
the underside of cabinet.
Use saber or keyhole saw to cut a rectangular opening
for vent.
Repeat steps 1-3 for the underside of the top of the
cabinet.
1.
.
.
4.
5
.
The actual size of the product is below, and the user
is installed according to the actual demand
Cabinet
front
C
D
A
B
E
F
G
H
A
B
C
D
E
F
G
H
(114mm)
4.13
(105mm)
0.98
(24.8mm)
(15.4mm)
(80mm)
(98.8mm)
(251mm)
(270mm)
C
D
A B
F
E
G
H
(Rectangle Ducted version)
A
B
C
D
(99mm)
(80mm)
(270mm)
(251mm)
E
F
G
H
(119mm)
(109.5mm)
(29.5mm)
(20mm)
Wiring From the Top
Wiring Through the Wall
3.15"
"
"
4.49"
"
"
"
0.61
3.89"
9.88"
10.63"
3.9"
3.15"
10.63"
9.88"
4.69"
4.29"
1.16"
0.79"
10
0.79”
7.09”
0.79”
7.09”
.25