1. Disconnect power.
2. Use UL listed wire connectors and connect white wires
(A) together.
3. Use UL listed wire connectors and connect black wires
(B) together.
Remove the power supply knockout from the top
or rear of the vent hood (depending on the incoming
location of your home power supply cable) and
install a UL listed or CSA approved 0.5” strain relief.
Lift the hood into final position
Feed enough electrical wire through the 0.5” UL listed
or CSA approved strain relief to make connections in
the terminal box. Tighten the strain relief screws.
Position the range hood so that the large end of
the keyhole slots are over the mounting screws.
Then push the hood toward the wall so that the screws
are in the neck of the slots. Tighten the mounting screws,
making sure the screws are in the narrow neck of slots.
Connect ventwork to hood.
Seal joints with vent clamps or duct tape to make
secure and airtight.
Check that back draft dampers work properly.
MAKE ELECTRICAL CONNECTION
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
.
4.
.
INSTALLING THE HOOD
A. White wires
B. Black wires
C. Green ground wire
D. UL listed wire connector
E. Home power supply cable
F. UL listed or CSA approved
Add the 2 rear 0.19" * 1.94" (0.49 * 5.0 cm)
rear mounting screws into the narrow neck of the
rear keyhole slots.
horizontal support
two wall studs in
.
.
8.
0.5” strain relief
A
A. Power supply knockout
13
These should screw into the
that was placed between the