LIST OF MATERIALS

Tools/Materials required

Pencil

Caulking gun and weatherproof caulking compound  

 

Flat-blade screwdriver

Phillips screwdriver

Saber or keyhole saw 

 

For cabinets with recessed bottoms:

Two - 2” (5.1 cm) wide 

ller strips. Length and 

thickness determined by recess dimensions.

Four 

at head wood screws or machine screws 

with washers and nuts (to attach 

ller strips).






ELECTRICAL REQUIREMENTS 

 

Observe all governing codes and ordinances.

Ensure that the electrical installation is adequate and in 

conformance with National Electrical Code, ANSI/NFPA 

70 (latest edition), or CSA Standards C22.1-94, Canadian 

Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edi-

tion) and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrician determine that

the ground path is adequate.

A copy of the above code standards can be obtained 

from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical 

circuit is required.

If the house has aluminum wiring, follow the  

procedure below:

Connect a section of solid copper wire to the 

pigtail leads.

Connect the aluminum wiring to the added 

section of copper wire using special conectors 

and/or tools designed and UL listed 

for joining copper to aluminum.

Follow the electrical connector manufacturer’s recom-

mended procedure. Aluminum/copper connection must 

conform with local codes and industry accepted wiring 

practices.

Wire sizes and connections must conform with 

the rating of the appliance as specified on th  

model/serial rating plate. 

The model/serial plate is located on the left side of 

the range hood.

Wire sizes must conform to the requirements of 

the National Electrical Code, ANSI/NFPA 70 (la 

est edition), or CSA Standards C22. 1-94, Canad

Electrical Code, Part 1 and C22.2 No. 0-M91 

(latest edition) and all local codes and ordinances.

1.

2.

an 

LIST OF MATERIALS

Parts included in your hood

3.25" x 10" Rectangular vent damper

2 - Grease filters

Use and Care / Installation Manual

Mounting screw kit

 

Vent clamps/duct tape as required 

UL listed or CSA approved 0.5” strain relief

Remove the protective film covering the product before 

putting into operation.

 






Wire nuts

Metal duct length to suit installation

Wire cutter / stripper

Measuring tape


Safety glasses

Gloves

Remove carton carefully. Wear gloves to protect

against sharp edges.

CAUTION

2 - plastic wall anchores

2 - 0.19" * 1.97" (0.49 * 5.0 cm) mounting screws 

4 - 0.2" * 0.75" (0.50 * 1.9 cm) mounting screws 

6 - 0.16" * 0.31" (0.40 * 0.8 cm) rectangular vent 

0.08” drill bit for cabinet pilot holes

4

E26 lampholder (Lamp not included)

damper screws 

NOT INCLUDED: E26 light bulb (120V, Max 9W, LED only)

Содержание CVU30W2AST

Страница 1: ...Free 3 months extension of the original limited warranty period Simply text a picture of your proof of purchase to 1 844 224 1614 The warranty extension is for the three months immediately following t...

Страница 2: ...d by the manufacturer If you have questions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power fro...

Страница 3: ...of failure to observe the instructions given here for installation maintenance and suitable use of the product The manufacturer further declines all respon sibility for injury due to negligence and t...

Страница 4: ...ection of copper wire using special conectors and or tools designed and UL listed for joining copper to aluminum Follow the electrical connector manufacturer s recom mended procedure Aluminum copper c...

Страница 5: ...conform to the Manufactured Home Construction Safety Standards Title 24 CFR Part 328 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard...

Страница 6: ...ve cleaners Cooktop Polishing Creme steel wool gritty washcloths or paper towels To avoid damage to the stainless steel do not use cleaners that contain chlorine Cleaning Method RANGE HOOD USE INSTRUC...

Страница 7: ...ING d r a z x a H k c o h S l a c i r t c e l E Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock NOTE The grease...

Страница 8: ...close as possible to where the vent system enters the heated portion of the house Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater than...

Страница 9: ...les locations Install horizontal s t a s d u t s l l a w o w t n e e w t e b 2 X 4 t s a e l t a t r o p p u the rear mounting screw holes location The horizontal support must be flush with the room s...

Страница 10: ...abinet cutouts From wall not cabinet frame Centerline 5 The actual size of the product is below and the user is installed according to the actual demand 3 The actual size of the product is below and t...

Страница 11: ...ne on the underside of cabinet Use saber or keyhole saw to cut a rectangular opening for vent Repeat steps 1 3 for the underside of the top of the cabinet 1 2 3 4 5 The actual size of the product is b...

Страница 12: ...able according to the National Electric Code or CSA standards and local codes and ordinances 1 For roof installations remove the top rectangular For wall installations remove the NOTE Remove the screw...

Страница 13: ...all so that the screws are in the neck of the slots Tighten the mounting screws making sure the screws are in the narrow neck of slots Connect ventwork to hood Seal joints with vent clamps or duct tap...

Страница 14: ...sure the wires on light switch are connected properly The hood is not venting out properly 1 The hood might be hanging to high from the cook top 2 The wind from the opened windows or opened doors in...

Страница 15: ...rice Every implied warranty including any statutory warranty or condition of merchantability RU WQHVV IRU SDUWLFXODU SXUSRVH LV GLVFODLPHG H FHSW WR WKH H WHQW SURKLELWHG E ODZ LQ ZKLFK FDVH VXFK ZDUU...

Страница 16: ......

Отзывы: