![Comfee CVU30W2AST Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/comfee/cvu30w2ast/cvu30w2ast_instruction-manual_2640920004.webp)
LIST OF MATERIALS
Tools/Materials required
Pencil
Caulking gun and weatherproof caulking compound
Flat-blade screwdriver
Phillips screwdriver
Saber or keyhole saw
For cabinets with recessed bottoms:
Two - 2” (5.1 cm) wide
fi
ller strips. Length and
thickness determined by recess dimensions.
Four
fl
at head wood screws or machine screws
with washers and nuts (to attach
fi
ller strips).
•
•
•
•
•
•
•
•
•
•
ELECTRICAL REQUIREMENTS
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 (latest edition), or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edi-
tion) and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that
the ground path is adequate.
A copy of the above code standards can be obtained
from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical
circuit is required.
If the house has aluminum wiring, follow the
procedure below:
Connect a section of solid copper wire to the
pigtail leads.
Connect the aluminum wiring to the added
section of copper wire using special conectors
and/or tools designed and UL listed
for joining copper to aluminum.
Follow the electrical connector manufacturer’s recom-
mended procedure. Aluminum/copper connection must
conform with local codes and industry accepted wiring
practices.
Wire sizes and connections must conform with
the rating of the appliance as specified on th
model/serial rating plate.
The model/serial plate is located on the left side of
the range hood.
Wire sizes must conform to the requirements of
the National Electrical Code, ANSI/NFPA 70 (la
est edition), or CSA Standards C22. 1-94, Canad
Electrical Code, Part 1 and C22.2 No. 0-M91
(latest edition) and all local codes and ordinances.
•
•
1.
2.
•
•
an
LIST OF MATERIALS
Parts included in your hood
3.25" x 10" Rectangular vent damper
2 - Grease filters
Use and Care / Installation Manual
Mounting screw kit
Vent clamps/duct tape as required
UL listed or CSA approved 0.5” strain relief
Remove the protective film covering the product before
putting into operation.
•
•
•
•
•
•
•
Wire nuts
Metal duct length to suit installation
•
Wire cutter / stripper
Measuring tape
•
•
Safety glasses
Gloves
Remove carton carefully. Wear gloves to protect
against sharp edges.
CAUTION
•
2 - plastic wall anchores
2 - 0.19" * 1.97" (0.49 * 5.0 cm) mounting screws
4 - 0.2" * 0.75" (0.50 * 1.9 cm) mounting screws
6 - 0.16" * 0.31" (0.40 * 0.8 cm) rectangular vent
0.08” drill bit for cabinet pilot holes
4
•
E26 lampholder (Lamp not included)
damper screws
NOT INCLUDED: E26 light bulb (120V, Max 9W, LED only)